Device maintenance and repair
7.1 Removing and installing hardware components
We are not liable for functional limitations caused by the use of third-party devices or
components.
Tools
You can make all repairs on the device with the following tools:
● T20 screwdriver for
● T10 screwdriver for all of the remaining screws
● Side cutter
7.1.2

Maintenance

To maintain high system availability, we recommend the preventative replacement of those
PC components that are subject to wear in accordance with the intervals for replacement
indicated in the table below.
Component
Drive
CMOS backup battery
Fan
Filter mat
To maintain high system availability, we recommend the preventative replacement of those
PC components that are subject to wear in accordance with the intervals for replacement
indicated in the table below.
7.1.3

Replacing filters

Requirement
● The device is disconnected from the power network
● The front panel cover is open
● A filter mat
68
– Device backplane
– Device fan
– PE terminal
The order number is A5E02399219.
Replacement interval:
3 years
5 years
3 years
Depending on the degree of soiling