Siemens SIMATIC IPC547D Operating Instructions Manual page 50

Table of Contents

Advertisement

Commissioning the device
4.3 Information on optional features
Note
The following figure and notes apply only to the delivery state of the device, assuming
that no changes or expansions have been made.
A RAID5 system, in contrast to a RAID1 system, is available only with hard disks in the
removable rack.
LED
HDD0 alarm
HDD1 alarm
HDD2 alarm
Please replace the faulty drive with a new one of the same type and capacity.
NOTICE
Hot swapping
In devices with removable rack, you can replace the drive without turning off the device.
Replacement in devices without a removable rack may only take place when the device is
turned off.
The new hard disk can be integrated into the RAID system at operating system level with
the RAID software. This is not possible at BIOS level.
Points to note if the hard disk is replaced when the computer is turned off
Only a hard disk that was active and functioning correctly when you booted can later be
included in the RAID system.
To be able to boot from the RAID system, you must place this first in the list of bootable
sources in the BIOS "Boot" setup menu. Otherwise, the system will boot from the hard disk
you have just installed and the message "Operating system not found" will be displayed.
50
RAID BIOS
RAID software SATA
Port 0
Device port 0
Port 1
Device port 1
Port 2
Device port 2
Installation location
connection on
the motherboard
SATA0
Removable rack
SATA1
Removable rack
SATA2
Removable rack
Operating Instructions, 06/2011, A5E03473780-01
Enclosure
labeling
0
1
2
SIMATIC IPC547D

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents