FX2N-16CCL-M CC-Link System Master Block
Buffer
Number
memory
SW0098
698
SW009C
69C
SW00B4
6B4
*3 Bits corresponding to as many as the number of occupied stations are set to ON.
*4 Only the bit corresponding to the head station number is set to ON.
The status is checked only when link starts up, and stored.
Name
Station number
H
*4
overlap status
Loading/parameter
H
consistency status
*3
Line test 1 result
H
Stores the overlap status in which the head station
number of each module does not overlap.
0: Normal
1: Station number overlap (only the head station number)
b15 b14 b13 b12
SW0098 ⎯
15
Numbers 1 to 15 above indicate station numbers
Stores the consistency with parameters.
0: Normal
1: Consistency error
Loading
Remote device station↔ Remote I/O station
*4
b15 b14 b13 b12
SW009C ⎯
15
Numbers 1 to 15 above indicate station numbers
Stores the line test 1 result.
0: Normal
1: Error
b15 b14 b13 b12
SW00B4 ⎯
15
Numbers 1 to 15 above indicate station numbers
Programming 9
Description
~
b3
b2
14
13
~
4
3
Parameter
~
b3
b2
14
13
~
4
3
~
b3
b2
14
13
~
4
3
9-14
b1
b0
2
1
b1
b0
2
1
b1
b0
2
1