Power Unit Will Not Lift Rated Load - Genie DPL-25S Service Manual

Hide thumbs Also See for DPL-25S:
Table of Contents

Advertisement

September 2016
Power Unit
Will Not Lift
Rated Load
Part No. 40462
Check the power source.
Note on DC models the
low
low battery indicator (red
voltage
LED) light would be on
indicting a low voltage
condition.
good
Check the pressure relief
valve setting. See
incorrect
Maintenance procedure,
Test the Lifting Capacity.
correct
Consult Genie Industries
Service Department.
DPL-25S • DPL-30S • DPL-35S Super Series
Section 5 - Troubleshooting Flow Charts
Charge the battery OR
check battery condition
and replace bad battery
OR use the appropriate
power cord OR consult
Genie Industries Service
Department.
Adjust the pressure relief
valve. See Repair
procedure, How to Adjust
the Pressure Relief
Valve.
Chart 10
5 - 23