Power Light Will Not Turn On - Dc Models - Genie DPL-25S Service Manual

Hide thumbs Also See for DPL-25S:
Table of Contents

Advertisement

September 2016
Power Light Will
Not Turn On -
DC Models
Be sure the keyswitch is
in the appropriate
position.
Be sure the Emergency
Stop buttons are pulled
up to the
position.
ON
Be sure the battery
cables are connected.
Be sure the ground
control box PC board
fuse is not blown.
Part No. 40462
Check the battery pack
0V DC
voltage.
12V DC
Check the voltage at
terminal 3 on the key
0V DC
switch N.O. contact. Put
Neg. lead of voltage
meter on grounding
terminal 10 of the 13 pole
terminal strip (J1).
12V DC
Check the voltage at
0V DC
terminal 4 on the key
switch N.O. contact.
12V DC
Check the voltage at
0V DC
terminal 1 on the
Emergency Stop button
N.C. contact.
12V DC
Check the voltage at
0V DC
terminal 2 on the
Emergency Stop button
N.C. contact.
12V DC
Check the voltage at
0V DC
terminal 3 (black wire) of
3 pole terminal strip (J2).
12V DC
Continued on the next
page.
DPL-25S • DPL-30S • DPL-35S Super Series
Section 5 - Troubleshooting Flow Charts
Charge the battery OR
check the battery
condition and replace a
bad battery.
Trace the black input wire
back to the motor start
solenoid and repair open
in the wire.
Replace the key switch
N.O. contact.
Trace the black wire from
terminal 1 on the
Emergency Stop N.C.
contact back to the key
switch N.O. contact and
repair open in wire.
Replace the Emergency
Stop button N.C.
contact.
Trace the black wire from
terminal 3 of the 3 pole
terminal strip (J2) back to
the Emergency Stop
button N.C. contact and
repair open in the wire.
Chart 2
5 - 5