1 Fully lower the platform, turn the machine off
and remove the key.
2 Remove the base cover from the power unit.
3 Remove the drain plug from the hydraulic
reservoir and completely drain the reservoir into
a container. Properly discard of oil.
5 Remove the power unit. See 3-3, How to
Remove the Power Unit - AC Models or 3-4,
How to Remove the Power Unit - DC Models.
6 Support the hydraulic reservoir with a lifting
device.
7 Remove the mounting fasteners from the
reservoir. Then remove the reservoir from the
power unit.
Note: It may be necessary to tap the side of the
reservoir with a soft rubber mallet to loosen it.
8 Remove the mounting fasteners from the pump.
Then remove the pump from the power unit.
When installing the reservoir, be
sure not to damage the o-ring.
Part No. 40462