Interlock Lights Will Not Turn On - Genie DPL-25S Service Manual

Hide thumbs Also See for DPL-25S:
Table of Contents

Advertisement

September 2016
Interlock
Lights Will
Not Turn On
Be sure the
keyswitch is in the
appropriate
position.
Be sure the
Emergency Stop
buttons are pulled
up to the on
position.
Be sure the power
light is on.
Be sure the unit is
set up according to
the operator's
manual.
Be sure the
outriggers are the
correct length.
Part No. 40462
light off
Check the power light.
light on
Check for power at
terminal 8 (black wire) on
the 13 pole terminal strip
(J1) located in the ground
0V DC
control box. Put Neg.
lead of voltage meter on
grounding terminal 10
(green/yellow wire).
12V DC
Disconnect the power
supply. Unplug the 18/7
cable quick disconnect
from the ladder-end
bad
junction box under the
ground control box and
inspect the male and
female connectors for
damage.
good
Check for power at the
black wires that are
0V DC
connected together with a
wire nut in the ladder-end
junction box.
12V DC
Continued on the next
page.
DPL-25S • DPL-30S • DPL-35S Super Series
Section 5 - Troubleshooting Flow Charts
Refer to either Chart 1 or
Chart 2.
Replace the P.C. board.
Repair or replace
damaged connectors.
Replace 18/7 cable from
the ground control box
because of open circuit in
black wire.
Chart 3
5 - 7