CONVERTING TO NATURAL OR L.P. GAS

Gas conversion must be done by a qualified
installer.
WARNING
Fire Hazard
Shut off gas supply line valve.
Make all conversions before turning
gas supply valve back on.
Failure to follow these instructions
could result in explosion, fire or other
injury.
The gas grill can be converted for use with
either natural or L.P. (Liquid Petroleum) gas.
To convert the grill, you will have to change the
orifices at the following locations:
(1) Infrared Burner
(3) Main Burners
(1) Smoker Burner
In addition to changing the orifices, you will
have to install the correct gas pressure regula-
tor. There is a separate regulator assembly for
use with each type of gas.
L.P. GAS ORIFICES
The L.P. Conversion Kit orifices are as follows:
(2) #57 (Infrared Burners)
(4) #55 (Grill Burners)
(2) #77 (Smoker Burners)
(1) Brass Elbow 3/8" Flare Fitting To 1/2"
NPT
(1) L.P. Hose & Regulator Assembly
NATURAL GAS ORIFICES
The Natural Gas Conversion Kit orifices are as
follows:
(2) #50 (Infrared Burners)
(4) #44 (Grill Burners)
(2) #66 (Smoker Burners)
(1) Convertible Regulator Assembly
(4" Natural & 10" L.P.)
CONVERTING THE GRILL
To convert the grill for use with either Natural or
L.P. gas, perform the following steps.
1.
Turn off and disconnect the gas supply
going to the grill.
2.
To convert the infrared burner:
a) Remove the screw from the rear ac-
cess panel and remove the panel.
Rear Access Panel
Screw
Continued on the next page.