APPENDIX B
Table B–9: MODBUS MEMORY MAP (Sheet 16 of 50)
ADDR
REGISTER NAME
4701
Breaker 1 name
4704
Breaker 1 mode
4705
Breaker 1 open
4706
Breaker 1 close
4707
Breaker 1 phase A / three-pole closed
4708
Breaker 1 phase B closed
4709
Breaker 1 phase C closed
470A
Breaker 1 external alarm
470B
Breaker 1 alarm delay
470D
Breaker 1 pushbutton control
470E
Breaker 1 manual close recall time
4710
Breaker 1 out of service
4711
Breaker 1 block open
4712
Breaker 1 block close
4713
Breaker 1 phase A / three-pole opened
4714
Breaker 1 phase B opened
4715
Breaker 1 phase C opened
4716
Breaker 1 operate time
4717
Breaker 1 events
4718
Reserved
4719
...Repeated for breaker 2
4732
...Repeated for breaker 3
474B
...Repeated for breaker 4
4764
...Repeated for breaker 5
477D
...Repeated for breaker 6
Demand (Read/Write Setting)
47D0
Demand Current Method
47D1
Demand Power Method
47D2
Demand Interval
47D3
Demand Input
Demand (Read/Write Command)
47D4
Demand Clear Record
Flexcurves A and B (Read/Write Settings)
4800
FlexCurve A (120 items)
48F0
FlexCurve B (120 items)
Modbus User Map (Read/Write Setting)
4A00
Modbus Address Settings for User Map (256 items)
User Displays Settings (Read/Write Setting) (16 modules)
4C00
User-Definable Display 1 Top Line Text
4C0A
User-Definable Display 1 Bottom Line Text
4C14
Modbus Addresses of Display 1 Items (5 items)
4C19
Reserved (7 items)
4C20
...Repeated for User-Definable Display 2
4C40
...Repeated for User-Definable Display 3
4C60
...Repeated for User-Definable Display 4
4C80
...Repeated for User-Definable Display 5
4CA0
...Repeated for User-Definable Display 6
4CC0
...Repeated for User-Definable Display 7
4CE0
...Repeated for User-Definable Display 8
4D00
...Repeated for User-Definable Display 9
4D20
...Repeated for User-Definable Display 10
4D40
...Repeated for User-Definable Display 11
4D60
...Repeated for User-Definable Display 12
4D80
...Repeated for User-Definable Display 13
GE Multilin
RANGE
---
0 to 1
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 1000000
0 to 1
0 to 1000000
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 2
0 to 1
---
0 to 2
0 to 2
0 to 5
0 to 65535
0 to 1
0 to 65535
0 to 65535
0 to 65535
---
---
0 to 65535
---
F35 Multiple Feeder Protection System
B.4 MEMORY MAPPING
UNITS
STEP
FORMAT
---
---
F206
---
1
F157
---
1
F300
---
1
F300
---
1
F300
---
1
F300
---
1
F300
---
1
F300
s
0.001
F003
---
1
F102
s
0.001
F003
---
1
F300
---
1
F300
---
1
F300
---
1
F300
---
1
F300
---
1
F300
s
0.001
F001
---
1
F102
---
---
---
---
1
F139
0 (Thrm. Exponential)
---
1
F139
0 (Thrm. Exponential)
---
1
F132
---
1
F300
---
1
F126
ms
1
F011
ms
1
F011
---
1
F001
---
---
F202
---
---
F202
---
1
F001
---
---
F001
DEFAULT
"Bkr 1"
0 (3-Pole)
0
0
0
B
0
0
0
0
0 (Disabled)
0
0
0
0
0
0
0
70
0 (Disabled)
---
2 (15 MIN)
0
0 (No)
0
0
0
" "
""
0
0
B-23