Table B–9: MODBUS MEMORY MAP (Sheet 6 of 50)
ADDR
REGISTER NAME
Source Demand (Read Only) (6 modules)
1E00
Source 1 Demand Ia
1E02
Source 1 Demand Ib
1E04
Source 1 Demand Ic
1E06
Source 1 Demand Watt
1E08
Source 1 Demand Var
1E0A
Source 1 Demand Va
1E0C
Reserved (4 items)
1E10
...Repeated for Source 2
1E20
...Repeated for Source 3
1E30
...Repeated for Source 4
1E40
...Repeated for Source 5
1E50
...Repeated for Source 6
Source Demand Peaks (Read Only Non-Volatile) (6 modules)
1E80
Source 1 Demand Ia Maximum
1E82
Source 1 Demand Ia Maximum Date
1E84
Source 1 Demand Ib Maximum
1E86
Source 1 Demand Ib Maximum Date
1E88
Source 1 Demand Ic Maximum
1E8A
Source 1 Demand Ic Maximum Date
1E8C
Source 1 Demand Watt Maximum
1E8E
Source 1 Demand Watt Maximum Date
1E90
Source 1 Demand Var
1E92
Source 1 Demand Var Maximum Date
1E94
Source 1 Demand Va Maximum
1E96
Source 1 Demand Va Maximum Date
1E98
Reserved (8 items)
1EA0
...Repeated for Source 2
1EC0
...Repeated for Source 3
1EE0
...Repeated for Source 4
1F00
...Repeated for Source 5
1F20
...Repeated for Source 6
Source Voltage THD And Harmonics (Read Only) (6 modules)
1F80
Source 1 Va THD
1F81
Source 1 Va Harmonics - 2nd to 25th (24 items)
1F99
Source 1 Vb THD
1F9A
Source 1 Vb Harmonics - 2nd to 25th (24 items)
1FB2
Source 1 Vc THD
1FB3
Source 1 Vc Harmonics - 2nd to 25th (24 items)
1FCB
...Repeated for Source 2
2016
...Repeated for Source 3
2061
...Repeated for Source 4
20AC
...Repeated for Source 5
20F7
...Repeated for Source 6
Breaker Arcing Current Actuals (Read Only Non-Volatile) (2 modules)
21E0
Breaker 1 Arcing Current Phase A
21E2
Breaker 1 Arcing Current Phase B
21E4
Breaker 1 Arcing Current Phase C
21E6
Breaker 1 Operating Time Phase A
21E7
Breaker 1 Operating Time Phase B
21E8
Breaker 1 Operating Time Phase C
21E9
Breaker 1 Operating Time
21EA
...Repeated for Breaker Arcing Current 2
GE Multilin
RANGE
0 to 999999.999
0 to 999999.999
0 to 999999.999
0 to 999999.999
0 to 999999.999
0 to 999999.999
---
0 to 999999.999
0 to 4294967295
0 to 999999.999
0 to 4294967295
0 to 999999.999
0 to 4294967295
0 to 999999.999
0 to 4294967295
0 to 999999.999
0 to 4294967295
0 to 999999.999
0 to 4294967295
---
0 to 99.9
0 to 99.9
0 to 99.9
0 to 99.9
0 to 99.9
0 to 99.9
0 to 99999999
0 to 99999999
0 to 99999999
0 to 65535
0 to 65535
0 to 65535
0 to 65535
F35 Multiple Feeder Protection System
B.4 MEMORY MAPPING
UNITS
STEP
FORMAT
A
0.001
F060
A
0.001
F060
A
0.001
F060
W
0.001
F060
var
0.001
F060
VA
0.001
F060
---
---
F001
A
0.001
F060
---
1
F050
A
0.001
F060
---
1
F050
A
0.001
F060
---
1
F050
W
0.001
F060
---
1
F050
var
0.001
F060
---
1
F050
VA
0.001
F060
---
1
F050
---
---
F001
---
0.1
F001
---
0.1
F001
---
0.1
F001
---
0.1
F001
---
0.1
F001
---
0.1
F001
2
kA
-cyc
1
F060
2
kA
-cyc
1
F060
2
kA
-cyc
1
F060
ms
1
F001
ms
1
F001
ms
1
F001
ms
1
F001
DEFAULT
0
0
0
0
B
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
B-13