Setting The Ip Address - Paradyne bitstorm 4800 Installation Manual

Hide thumbs Also See for bitstorm 4800:
Table of Contents

Advertisement

4. Configuration

Setting the IP Address

The IP address of the Management Module must be set before the BitStorm 4800
can be remotely managed.
Procedure
To set the IP address of the Management Module:
4-4
1. At the IAC# prompt, type:
configure management address address mask gateway
Where:
— address is the IP address to be assigned to the Management Module
— mask is the IP subnet mask for the specified address
— gateway is the default gateway IP address
For example:
conf man addr 135.26.10.37 255.255.255.0 135.26.10.254
2. Press Enter. The prompt changes to IAC#! to show that the configuration
change has yet to be saved.
3. Type save and press Enter.
4. To verify that the address has been set, type:
show management ip
The CLI displays the IP address, subnet mask, and default gateway address.
April 2002