TIM1500-12 and TIM1500-24 T1 Inverse Multiplexer
Installation Instructions
Document Number TIM1-A2-GZ40-00
September 2004
Contents

Software and Firmware License Agreement

TIM1-A2-GZ40-00
................................................................................................... 3
..................................................................................... 3
...................................................................................... 6
.............................................................................................. 10
........................................................................................... 11
.................................................................................... 11
................................................................................................... 12
................................................................................................... 13
...................................................................................................... 15
..................................................................................... 16
ONCE YOU HAVE READ THIS LICENSE AGREEMENT AND AGREE TO ITS
TERMS, YOU MAY USE THE SOFTWARE AND/OR FIRMWARE INCORPORATED
INTO THE PARADYNE PRODUCT. BY USING THE PARADYNE PRODUCT YOU
SHOW YOUR ACCEPTANCE OF THE TERMS OF THIS LICENSE AGREEMENT.
IN THE EVENT THAT YOU DO NOT AGREE WITH ANY OF THE TERMS OF THIS
LICENSE AGREEMENT, PROMPTLY RETURN THE UNUSED PRODUCT IN ITS
ORIGINAL PACKAGING AND YOUR SALES RECEIPT OR INVOICE TO THE
LOCATION WHERE YOU OBTAINED THE PARADYNE PRODUCT OR THE
LOCATION FROM WHICH IT WAS SHIPPED TO YOU, AS APPLICABLE, AND YOU
WILL RECEIVE A REFUND OR CREDIT FOR THE PARADYNE PRODUCT
PURCHASED BY YOU.
September 2004
...................................................... 1
.......................................................................... 3
.............................................................. 4
........................................................................ 5
......................................................................... 8
........................................................................ 15
........................................... 17
1

Advertisement

Table of Contents
loading

Summary of Contents for Paradyne TIM1500

  • Page 1: Table Of Contents

    TIM1500-12 and TIM1500-24 T1 Inverse Multiplexer Installation Instructions Document Number TIM1-A2-GZ40-00 September 2004 Contents Software and Firmware License Agreement Product Documentation Online Release Notes Unpacking the TIM1500 Verifying the TIM1500 Switch Settings Installing the TIM1500 in a BAC Connecting the T1 Line...
  • Page 2 The terms and conditions of this License Agreement (the “Agreement”) will apply to the software and/or firmware (individually or collectively the “Software”) incorporated into the Paradyne product (the “Product”) purchased by you and any derivatives obtained from the Software, including any copy of either. If you have executed a separate written agreement covering the Software supplied to you under this purchase, such separate written agreement shall govern.
  • Page 3: Product Documentation Online

    If you are not sure of the proper static control precautions, contact your nearest sales or service representative. Unpack and inspect the TIM1500. If there is visible damage, do not attempt to connect the device; contact your sales or service representative. TIM1-A2-GZ40-00...
  • Page 4: Verifying The Tim1500 Switch Settings

    Verifying the TIM1500 Switch Settings The TIM1500 has a bank of eight switches at the rear of the module (opposite the faceplate). Switches are numbered from left to right, 1–8. All eight switches should be in the default up (ON) position. Switches 1 and 4–8 are not used.
  • Page 5: Installing The Tim1500 In A Bac

    Procedure 1. Align the TIM1500 with the slot module guides of the chosen slot for installation (slot 1–12 in the 12000 and 12000E or slot 1–4 in the 4000 and 4000E).
  • Page 6: Connecting The T1 Line

    Connecting the T1 Line T1 cables must be connected according to the BAC slot in which the TIM1500 was installed. For example, a TIM15000 installed in Slot 3 of an 12000E uses the RJ21 connectors labeled 3A and 3B. 12000E and 4000E Each interface module slot on the 12000E and 4000E has two corresponding RJ21 connectors located on the back of the chassis.
  • Page 7 TIM1500 T1 ports 1–12. Although the TIM1500-24 can function in an 12000 or 4000, you will not be able to utilize ports 13–24; the 12000 and 4000 do not have the second row of B connectors necessary to support additional T1 ports.
  • Page 8: Attaching The Rj21 Connectors

    Attaching the RJ21 Connectors 12000 and 12000E Procedure To attach RJ21 connectors to the 12000 or 12000E: 1. Detach the hook and loop fastener strap and pull it open to the right, leaving it looped under the connector frame on the right side. Slide the RJ21 connector of your T1 cable underneath the strap and press it firmly into the RJ21 connector on the chassis.
  • Page 9 3. Pull the hook and loop fastener strap to the right, making sure that it is snug against the connector, and then pull the strap back across to the left, sticking it to itself across the top of the connector. Tuck the tab at the end of the strap down to the left of the connector frame so it is out of the way of other connections.
  • Page 10: Rj21 Port Pinouts

    Table 1, A (12000E bottom row, 4000E left side, 12000 and 4000). Pins 13 and 38 are not used. Table 1. A Connectors TIM1500 T1 PORTS RJ21 PINS Table 2, B (12000E top row and 4000E right side). Pins 13 and 38 are not used.
  • Page 11: Remote Connection

    The T1 equipment to which a TIM1500 is connected must also be T1 loop bonding capable in order for the TIM1500 to establish a loop bonded connection. Refer to the Product to Product T1 Loop Bonding Compatibility document (COMP-A2-GK43) on Paradyne’s website.
  • Page 12: Led Indicators

    INDICATION ADDITIONAL INFORMATION TIM1500 is operational If the Power LED is not illuminated, it is unlikely the TIM1500 is receiving power. None of the LEDs will be illuminated. T1 connection is established The T1 link is operational and traffic is and active flowing.
  • Page 13: T1 Parameters

    Tx Buildout is the attenuation level of the T1 line. The shorter the distance between the TIM1500 and a remote T1 modem, the more line attenuation is required in order to prevent the incoming amplitude of the T1 signal from becoming too strong for repeaters, switches and other T1 transmission equipment that may be encountered along the line.
  • Page 14 Loop (default in subscriber mode) – Timing is derives from an intermediate device on the T1 line. NOTE: Local timing is the default for a TIM1500 in T1 provider mode. Default for a TIM1500 in subscriber mode is Loop and cannot be modified.
  • Page 15: Configuration And Management

    BAC management and interface module parameter configuration. Data Storage Upon initial power up of the BAC, default parameters of the TIM1500 will remain in place unless changed via the NMS, CLI, or SNMP. Once changed, new configurations will automatically be recorded in both the Random Access Memory (RAM) of the TIM1500 and the Non-Volatile Random Access Memory (NVRAM) of the MUM.
  • Page 16: Regulatory Compliance

    Part 68 of the FCC rules, using the following standard jack types: „ RJ48H: TIM1500-12, TIM1500-24, TAM1500-12 or TNE1500-P-12-AC/DC „ RJ48C: TNE1520-P, TNE1520-S, TNE1500-P, TNE1500-S, MIM-2T1, UIM-2T1 or UIM-T1 In the unlikely event that this equipment harms the telephone network, the telephone company can temporarily disconnect your service.
  • Page 17: Warranty, Sales, Service, And Training Information

    Industry Canada Class A Equipment This Class A digital apparatus complies with Canadian ICES-003. Cet appareil numérique de la Classe A est conforme à la norme NMB-003 du Canada. T1 Equipment Notice: The Industry Canada label identifies certified equipment. This certification means that the equipment meets telecommunications network protective, operational, and safety requirements as prescribed in the appropriate Terminal Equipment Technical Requirements documents.