Genie ZX-135/70 Service And Repair Manual page 165

Hide thumbs Also See for ZX-135/70:
Table of Contents

Advertisement

October 2016
Error Source
Primary Boom Up/Down
buttons on TCON
Primary Boom Ext/Ret
buttons on TCON
Primary Boom Length
Primary Up/Down Speed
Primary Extend/Retract
Speed
Primary Boom Extend Valve Fault Check
Primary Boom Retract Valve
Primary Boom Up Valve
Primary Boom Down Valve
Primary Lock-Out Valve #1
Primary Lock-Out Valve #2
Secondary Boom
Up/Down/Extend/Retract
Flow Valve
Part No. 1268558
Error Type
Fault Check (both
Primary Boom Up/Down disabled,
buttons pressed)
display message on LCD
Fault Check (both
Primary Boom Ext/Retract disabled,
buttons pressed)
display message on LCD
Fault Check
Stop all boom functions, allow only
(unknown length)
boom retract, once fully retracted allow
boom down. Display message on LCD
Not calibrated
Display message on LCD and allow
operation at default speed
Not calibrated
Display message on LCD and allow
operation at default speed
Limited Speed and Direction frozen at
zero and neutral, Alarm sounds
Not calibrated
Normal function except threshold for
one or the other direction is zero.
Display message on LCD
Just calibrated
Initiate one second beep of audible
warning device
Value Too High
Limited Speed and Direction frozen at
zero and neutral, Alarm sounds
Value Too Low
Limited Speed and Direction frozen at
zero and neutral, Alarm sounds
ZX-135/70
Effects
Check ribbon and connector from
membrane switch. If necessary replace
membrane switch.
Check ribbon and connector from
membrane switch. If necessary replace
membrane switch.
Check primary boom retracted and
extended switches for proper contact
with the boom. Readjust or shim switch
as necessary.
Perform auto calibrate procedure.
Perform auto calibrate procedure.
Check for defective or damaged wiring.
Check for an open or shorted valve coil.
Repair or replace as necessary.
Perform calibration procedure
Self-clearing (transient)
Check for opens in the wiring or a bad
ground. Replace coil if necessary
Check for opens in the wiring or a bad
ground. Replace coil if necessary
Service and Repair Manual
Fault Codes
Recovery Actions
153

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Z-135/70Genie z13505-101Genie z13513-2000

Table of Contents