Genie ZX-135/70 Service And Repair Manual page 112

Hide thumbs Also See for ZX-135/70:
Table of Contents

Advertisement

Service and Repair Manual
Display Module
Screen or Menu
Sensor Calibration
With key switch
enter button and turn key switch to on
(software version
position.
4.01 and higher)
Release the enter button and press
(plus)(enter)(enter)(plus).
100
Procedure
, press and hold the
OFF
ZX-135/70
Description
Set unit X-axis to gravity
Set unit Y-axis to gravity
Set platform level to gravity (YES/NO)
Platform level sensor millivolts/degree
Delete axles angle sensors calibration?
(YES/NO)
YES: Axle angle fully retracted (YES/NO)
YES: Axle angle fully extended (YES/NO)
Delete all steer sensors calibrations?
(YES/NO)
Delete blue end blue side steer sensor (FL)
calibration? (YES/NO)
Delete yellow end blue side steer sensor
(RL) calibration? (YES/NO)
Delete blue end yellow side steer sensor
(FR) calibration? (YES/NO)
Delete yellow end yellow side steer sensor
(RR) calibration? (YES/NO)
Delete secondary boom angle sensor
calibration? (YES/NO)
Secondary boom fully lowered? (YES/NO)
Secondary boom fully raised? (YES/NO)
Delete primary boom angle sensor
calibration? (YES/NO)
Primary boom fully lowered? (YES/NO)°
Primary boom fully raised? (YES/NO)°
Delete jib level angle sensor calibration?
(YES/NO)
Jib level cylinder fully extended? (YES/NO)
Jib level cylinder fully retracted? (YES/NO)
October 2016
Range or
Selection
Use +/- buttons
to adjust
Part No. 1268558