49 Press the plus button to select YES, then
press the enter button to accept.
50 Turn the key back to the run position and
remove the key from the bypass/recovery key
switch. Insert the key into the main key switch
and turn it to ground controls.
Note: Be sure that the bypass/recovery key switch
is in the run position before attempting to operate
the machine.
51 Wait approximately 20 seconds and turn the
machine off by pressing the red Emergency
Stop button in.
52 Remove the fastener that was temporarily
installed. Close the control box door and install
the door retaining fasteners.
Note: When the control box door is closed, the
calibration toggle switch is automatically activated
to exit out of calibration mode.
53 Pull out the red Emergency Stop button. Start
the engine and lower the boom to the stowed
position. Be sure there are no calibration faults
shown on the display.
Perform secondary boom angle test. Refer to
Maintenance Procedure in the appropriate Service
or Maintenance Manual, Test the Secondary Boom
Angle Sensor.