Manifolds
Function Manifold Components, continued
The function manifold is mounted to the turntable next to the ground controls.
Index
Description
No.
17
Proportional solenoid
valve
18
Differential sensing valve,
150 psi / 10.3 bar
19
Proportional solenoid
valve
20
Check valve, 5 psi /
0.34 bar
21
Proportional solenoid
valve
22
Proportional solenoid
valve
23
Differential sensing valve,
150 psi / 10.3 bar
24
Relief valve, 2600 psi /
179 bar
25
Proportional solenoid
valve
26
Differential sensing valve,
150 psi / 10.3 bar
110
Schematic Item Function
R
Turntable rotate circuit
DD
Turntable rotate circuit, regulates
pressure drop across turntable
rotate proportional valve
U
Secondary boom up/down circuit
V
Pump circuit
GG
Secondary boom extend/retract
circuit
T
Primary boom extend/retract circuit
P
Primary boom extend/retract
circuit, regulates pressure drop
across primary boom extend/retract
proportional valve
X
Primary boom extend
S
Primary boom up/down circuit
O
Primary boom up/down circuit,
regulates pressure drop across
primary boom up/down proportional
valve
ZX-135/70
October 2016
Torque
33-37 ft-lbs / 45-50 Nm
30-35 ft-lbs / 41-47 Nm
50-55 ft-lbs / 68-75 Nm
90-100 ft-lbs / 122-136 Nm
50-55 ft-lbs / 68-75 Nm
33-37 ft-lbs / 45-50 Nm
30-35 ft-lbs / 41-47 Nm
20-25 ft-lbs / 27-34 Nm
50-55 ft-lbs / 68-75 Nm
30-35 ft-lbs / 41-47 Nm
Part No. 1268558