Genie ZX-135/70 Service And Repair Manual page 113

Hide thumbs Also See for ZX-135/70:
Table of Contents

Advertisement

October 2016
Screen or
Menu
Options
With key switch
the enter button and turn key switch
to on position.
Release the enter button and press
(minus)(minus)(plus)(plus).
Part No. 1268558
Procedure
, press and hold
OFF
ZX-135/70
Description
Boom Function Limit
(NO LT/EXT LT)
AC Generator
(NONE/BELT/HILO/HYDRL/GHG10)
Alarm No (NO AL)/Motion (MO AL)
Travel (TR AL)/ Descent (DE AL)/
Travel and Descent (TD AL)
Lift/Drive No (NO CO)/ Drive cut out
while not stored (DCONS)/ Lifting or
driving (LORDR)
Proximity Kill Switch (NONE/PROX)
Platform Overload
(NONE/WARN/CUTPT/CUTAL/PLFTS)
Work Li ghts (YES/NO)
Flashing Beacon (NO/YES)
Drive Lights (NO/YES)
Disable Steer Mode Change while
Driving (NO/YES)
Rocker Switch (NO/YES)
Chassis Tilt Cutout (NONE),
Chassis Tilt Cutout (COALL)
Drive Tilt Cutout (CODRV)
Foot Switch Lockout (0-30 minutes)
Platform Always Level to Gravity
(NO/YES)
Axle Motion Only While Driving
(NO/YES)
Service and Repair Manual
Display Module
Range or
Selection
No LT= No limit;
EXT LT=
secondary boom
extend inhibited
Cutout All
Cutout Drive
30.0 max and
0.0 min, 10.0
(default)
Holding +/- button
will cause display
to scroll through
options or
increment number
settings
automatically at
0.2 min
increase/decrease
101