Remove the key from the main key switch.
Insert the key into the bypass/recovery key
switch and turn it to the bypass position.
Note: The angle sensor calibration values will not
be saved correctly unless the key switch is in the
bypass position and the calibration toggle switch is
activated.
1 Run
2 Bypass
3 Recovery
7
Press and hold the enter button on the ground
control panel while pulling out the ground
controls red Emergency Stop button to the on
position. Hold the enter button for
approximately 5 seconds and then release it.
8
Enter sensor calibration mode by pressing the
buttons at the ground controls in the following
sequence: (plus)(enter)(enter)(plus).
Part No. 1268558
Turntable Rotation Components
9
Press the enter or previous button on the
LCD screen until SET UNIT X AXIS LEVEL TO
GRAVITY is displayed.
10 Place a digital level that has ben calibrated to
gravity on the X axis of the turntable.
Note: Illustrations shown at the platform end of the
machine.
positive degree side slope
negative degree side slope
ZX-135/70
Service and Repair Manual
X axis
139