Genie ZX-135/70 Service And Repair Manual page 174

Hide thumbs Also See for ZX-135/70:
Table of Contents

Advertisement

Service and Repair Manual
Fault Codes
Error Source
Safety Turntable Level
Sensor Y Direction
Platform Level Sensor Y
Direction
Platform Rotate Clockwise
Valve
Platform Rotate
Counterclockwise Valve
Jib Extend /Retract Valve
Jib Up/Down Flow Valve(s)
162
Error Type
Value at 5.0 V
Primary up and extend disabled, Alarm
sounds
Value Too High
Value Too Low
Value at 0 V
Out of Tolerance
Just calibrated
Initiate one second beep of audible
warning device
Value at 5.0 V
Primary up and extend disabled, Alarm
sounds
Value Too High
Value Too Low
Value at 0 V
Just calibrated
Initiate one second beep of audible
warning device
Fault Check
Fault Check
Fault Check
Fault Check
Not calibrated
Normal function except threshold for
one or the other direction is zero.
Display message on LCD
Just calibrated
Initiate one second beep of audible
warning device
Value Too High
Limited Speed and Direction frozen at
zero and neutral, Alarm sounds
Value Too Low
ZX-135/70
Effects
Check that SCON is grounded
Replace SCON
Self-clearing (transient)
Check that SCON is grounded
Self-clearing (transient)
Check for defective or damaged wiring.
Check for an open or shorted valve coil.
Repair or replace as necessary.
Check for defective or damaged wiring.
Check for an open or shorted valve coil.
Repair or replace as necessary.
Perform calibration procedure
Self-clearing (transient)
Check for opens in the wiring or a bad
ground. Replace coil if necessary
October 2016
Recovery Actions
Part No. 1268558