Genie ZX-135/70 Service And Repair Manual page 194

Hide thumbs Also See for ZX-135/70:
Table of Contents

Advertisement

Service and Repair Manual
Deutz TD 2.9 L4 Engine Fault Codes
SPN = Suspect Parameter Number
FMI = Failure Mode Identifier
KWP = Keyword Protocol
SPN
FMI KWP Description
523960
0
1458 High exhaust gas temperature
EGR cooler downstream;
warning threshold exceeded
523960
1
1012 Physical range check low for
EGR cooler downstream temp.
523960
1
1459 High exhaust gas temperature
EGR cooler downstream; shut off
threshold exceeded
523980
14
1187 Bad quality of reduction agent
detected
523981
11
918
Urea-tank without heating
function (heating phase)
523982
0
360
Powerstage diagnosis disabled;
high battery voltage
523982
1
361
Powerstage diagnosis disabled;
low battery voltage
523988
3
1245 Charging lamp; short circuit to
battery
523988
4
1246 Charging lamp; short circuit to
ground
523988
5
1243 Charging lamp; open load
523988
12
1244 Charging lamp; over temp.
523998
4
1327 Injector cylinder bank 2 slave;
short circuit
523999
12
1328 Injector powerstage output Slave
defect
524014
1
1254 Air pressure glow plug flush line;
below limit
182
SPN
FMI KWP Description
524016
2
1259 Amount of air is not plausible to
524016
2
1260 Calculated amount of air is not
524016
11
1258 HFM sensor; electrical fault
524021
11
1263 Burner fuel line pipe leak behind
524024
11
1302 Deviation of the exhaust gas
524028
2
1431 CAN message PROEGRActr;
524029
2
1432 Timeout Error of
524030
7
1440 EGR actuator; internal error
524031
13
1441 EGR actuator; calibration error
524032
2
1442 EGR actuator; status message
524033
7
1443 EGR actuator; due to overload in
524034
3
1438 Disc separator; short circuit to
524034
4
1439 Disc separator; short circuit to
524034
5
1436 Disc Separator; open load
524034
12
1437 Disc Separator; powerstage over
ZX-135/70
October 2016
pump speed
plausible to HFM reading
Shut Off Valve
temp. setpoint to actual value
downstream (DOC) too high
plausibility error
CAN-Receive-Frame
ComEGRActr - exhaust gas
recirculation positioner
EGRCust is missing
Save Mode
battery
ground
temperature