NOTE: You can always exit from any X-PRESS function at any time by
pressing the X-PRESS push button once. After a short delay the procedure is
cancelled.
NOTE: If you have used this procedure to configure Matrix 120 go to step 6.
Reset Reader to Factory Default Environment (Optional)
If it ever becomes necessary to reset the reader's Environment parameters to their factory
default values, you can perform this procedure by holding the X-PRESS push button pressed
while powering up the reader. You must keep the X-PRESS push button pressed until all
LEDs blink simultaneously for about 3 seconds. Release and re-press the button
during this LED blinking sequence.
All the device's Environment parameters are reset including the default IP Address. The
Matrix 120 emits 3 high pitched beeps and after a few seconds enters run mode.
Any previously saved configurations on the device will remain in memory, but the Default
configuration is set as the startup configuration.
NOTE: If you release the button while the LEDs are all on continuously (after
the blinking phase), the reader will enter the Loader program sequence and
the LEDs will begin to cycle through various patterns. Just cycle power to
return to run mode.