Datalogic Matrix 120 Reference Manual page 16

Hide thumbs Also See for Matrix 120:
Table of Contents

Advertisement

1
CBX100/CBX500 Pinout for Matrix 120
The table below gives the pinout of the CBX100/CBX500 terminal block connectors. Use this
pinout
only
when the Matrix 120 reader is connected to the CBX100/CBX500 by means of
the CAB-1011 accessory cable:
Vdc
Power Supply Input Voltage +
GND
Power Supply Input Voltage -
Earth
Protection Earth Ground
Power Source – External Trigger
+V
I1A
External Trigger A (polarity insensitive)
I1B
External Trigger B (polarity insensitive)
Power Reference – External Trigger
-V
Power Source – Inputs
+V
I2A
Input 2 A (polarity insensitive)
I2B
Input 2 B (polarity insensitive)
Power Reference – Inputs
-V
+V
Power Source - Outputs
-V
Power Reference - Outputs
O1+
Output 1 + opto-isolated and polarity sensitive
O1-
Output 1 - opto-isolated and polarity sensitive
O2+
Output 2 + opto-isolated and polarity sensitive
O2-
Output 2 - opto-isolated and polarity sensitive
Shield
Cable shield connected to chassis and 17-pin connector shell
* Do not leave floating, see par. 4.2.2 for connection details.
CAUTION: Do not connect GND and SGND to different (external) ground
references. GND and SGND are internally connected through filtering circuitry
which can be permanently damaged if subjected to voltage drops over 0.8
Vdc.
4
CBX100/500 Terminal Block Connectors
Input Power
Inputs
Outputs
Auxiliary Interface
Matrix 120 has no Auxiliary Interface
ID-NET
Matrix 120 has no ID-NET Interface
Main Interface
RS232
TX
RX
-
-
SGND
MATRIX 120™ REFERENCE MANUAL
RS422 Full-Duplex
TX+
*RX+
TX-
*RX-
SGND

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents