On-Board Ethernet Connector; Inputs - Datalogic Matrix 120 Reference Manual

Hide thumbs Also See for Matrix 120:
Table of Contents

Advertisement

ALTERNATIVE CONNECTIONS

ON-BOARD ETHERNET CONNECTOR

A Standard M12 D-Coded female connector is provided for the on-board Ethernet
connection. This interface is IEEE 802.3 10 BaseT and IEEE 802.3u 100 BaseTx compliant.
Figure 71 - M12 D-Coded Female Ethernet Network Connector
Pin
1
2
3
4

INPUTS

There are two non opto-isolated inputs available on the M12 17-pin connector of the
reader: Input 1 (External Trigger) and Input 2, a generic input.
The electrical features of both inputs are:
NPN
PNP
* The OFF state is guaranteed even if the input is floating.
The relative pins on the M12 17-pin connector are:
Pin
6
13
2
NOTE: These inputs become opto-isolated when connected to the CAB-
1011 accessory cable and acquire the electrical features described in par.
4.4.
3
On-Board Ethernet Network Connector Pinout
Name
Function
TX +
Transmitted data (+)
RX +
Received data (+)
TX -
Transmitted data (-)
RX -
Received data (-)
INPUT
V
IN
OFF*
4 V
ON
0 V
OFF*
0 V
ON
4 V
Name
Function
IN1
External Trigger (referenced to GND)
IN2
Input 2 (referenced to GND)
GND
Power Supply input voltage -
4
1
2
Min.
V
Max.
IN
30 V
2.5 V
2.5 V
30 V
A
I
Max
IN
.
0 mA
0.3 mA
0 mA
3.5 mA
123