BE-60
4. Eco Mode Control
General
D Eco mode control limits the air conditioning system performance during heating and cooling and
increases the amount of engine OFF time, thus improving the fuel economy.
D Eco mode control is activated by pressing the momentary type ECO switch on the instrument panel.
"ECO" is displayed on the heater control panel LCD during this control.
D Eco mode control during heating and cooling, and its cancel conditions are shown in the table below.
ECO Mode Control
D Stops PTC heater operation.
D Increases the amount of engine OFF time.
Heating
D Prohibits BI-LEVEL mode during AUTO
Mode
operation.
D Limits power consumption by the electric
Cooling
inverter compressor based on the room
Mode
temperature.
Heating Mode
D The required engine coolant temperature when starting the engine when the vehicle is stopped differs
from that when the vehicle is running. Therefore, the fuel economy has been improved by increasing the
amount of engine-off time when the vehicle is stopped.
D When the ECO switch is turned ON during heating, the A/C ECU stops the PTC heater operation.
Therefore, it takes a longer time to reach the set temperature than while the ECO switch is OFF.
D Engine coolant temperatures fluctuate greatly between when the vehicle is running and the vehicle is
stopped. The blower level changes accordingly.
D The hysteresis, which is used while the ECO switch is ON, is provided to prevent the blower level from
hunting due to fluctuations in the engine coolant temperature.
Engine Coolant
Temperature
High
Air Flow
Volume
Low
Engine Coolant Temperature
BODY ELECTRICAL - AIR CONDITIONING
High
Low
Target Outlet Air Temperature
Air Flow
Volume
High
ECO Switch OFF
Eco Mode Cancel Conditions
D DEF or FOOT DEF mode is selected.
D MAX HOT temp. setting
D ECO switch OFF
D MAX COLD temp. setting
D ECO switch OFF
Vehicle running
Engine OFF
Engine ON
Engine OFF
Engine ON
Vehicle stopped
High
Hysteresis
High
Low
Engine Coolant Temperature
ECO Switch ON
02HBE42Y
High
02HBE43Y