BE-50
3. Condenser
D A MF (Multi-Flow) type condenser is used. The condenser consists of two cooling portions: a condensing
portion and a super-cooling portion, and gas-liquid separator (modulator) are integrated together. This
condenser uses a sub-cool cycle that offers excellent heat-exchange performance.
D In the sub-cool cycle, after the refrigerant passes through the condensing portion of the condenser, both
the liquid refrigerant and the gaseous refrigerant that could not be liquefied are cooled again in the
super-cooling portion. Thus, the refrigerant is sent to the evaporator in an almost completely liquefied
state.
Gaseous
Refrigerant
Liquid
Refrigerant
BODY ELECTRICAL - AIR CONDITIONING
Condensing Portion
Super-Cooling Portion
Modulator
02HBE39Y