Pu Jog Operation - Mitsubishi Electric FR-PU07 Instruction Manual

Parameter unit
Hide thumbs Also See for FR-PU07:
Table of Contents

Advertisement

OPERATION

4.2.2 PU jog operation

Hold down the FWD-key or REV-key to perform operation, and
release it to stop.
Jog operation cannot be performed in the following cases:
During motor operation.
The Pr. 15 "Jog frequency" is less than the Pr. 13 "Starting
frequency".
Example: To operate at the PU jog running frequency of 8 Hz
Operation Procedure
Switch to the PU operation mode.
If the operation mode indication is not
[PU], refer to page 71 and switch to the
PU operation mode.
The frequency for jog operation can be
set with Pr. 15 "Jog frequency" and the
acceleration/deceleration time with
Pr. 16 "Jog acceleration/deceleration
time" both in the parameter unit.
(Refer to page 21 for the parameter set-
ting method.)
Initial value:
Pr. 15 = 5 Hz, Pr. 16 = 0.5 s
Press the PU-key, then the SHIFT-key.
The PU jog operation mode is selected,
and the PU jog frequency setting
screen appears on the display. To
change the frequency, enter the value
and press the WRITE-key.
74
Image
1. Power on -> Operation mode check
ON
REMARKS
The jog operation mode may also be selected from the FUNC-key. (Re-
2. Parameter setting
fer to page 49).
3. Jog operation mode selection
Operation Procedure
Press the FWD-key or the REV-key.
The display changes to the monitor
screen. Hold down the key to perform
operation and release it to stop.
Press the PU-key.
The inverter exits from the jog opera-
tion mode and returns to the ordinary
PU operation mode.
Image
4. Operation
or
5. Exit from jog operation mode