OPERATION
4.3.2 Entering the running frequency from outside and making start and stop from the PU
(Pr. 79 = 4)
Operation Procedure
Switch the power on.
Set "4" in Pr. 79 "Operation mode se-
lection".
The external/PU combined operation
mode is selected and the operation
mode indication on the display changes
to "PU + E".
Enter the external frequency com-
mand.
Select the multi-speed signal or turn the
frequency setting potentiometer.
76
Image
1. Power on
ON
2. Operation mode selection
3. Running frequency
High speed
Middle speed
Low speed
or
ON
Operation Procedure
Press the FWD-key or the REV-key of
the parameter unit.
The motor starts running, and the state
of the output frequency is shown on the
display.
The starting terminals (STF, STR) of
the inverter are invalid.
The inverter may also be started by
pressing the PU FWD-key or REV-
key and then inputting the frequency
command.
Press the STOP/RESET-key of the pa-
rameter unit.
The motor is decelerated to a stop.
Image
4. Start
or
5. Stop
Stop