FUNCTION MENU

3.2.2 Selection of PU operation (direct input)

You can select the PU operation mode to set PU operation frequency.
Description
Press the FUNC-key
The function menu is called.
Using the Cursor-key ▼, move the cur-
sor to "2 PU Oper".
Press the READ-key.
The menu on the right appears.
Make sure that the cursor is located at
"1 PU".
If not, move the cursor with the Cursor-
keys ▲/▼.
Press the READ-key.
The PU operation mode is selected and
the frequency setting screen appears.
Enter the set frequency using the
number keys and press the WRITE-
key.
The frequency setting is complete.
48
Display
Description
1
MONITOR
Press the FWD- or REV-key to perform
2 PU Oper
forward or reverse rotation with the set
3 Pr.List
frequency.
4 Pr.Clear
1 MONITOR
REMARKS
2
PU Oper
Press the ▲-key to call the frequency setting screen any time.
3 Pr.List
4 Pr.Clear
1
PU:Directly
2 JOG:Jogging
Freq Set
SET
0.00Hz
0~400Hz
Freq Set
SET
50.00Hz
Completed
Display
READ:
List
50.00
Hz
STF FWD
PU