FUNCTION MENU
Writing the parameter setting copied to FR-PU07 to the
inverter
Description
Writing the parameter setting copied to FR-PU07to the inverter.
Press the FUNC-key
The function menu appears.
Select the "multiple copies".
Using the Cursor-keys ▲/▼, move the
cursor to "12 PRCpy set" and press the
READ-key.
Select the copy area.
Point the cursor to the copy area that
stores the parameter settings to be writ-
ten to the inverter, and press the
READ-key.
Select the "WRITE".
Using the Cursor-keys ▲/▼, point the
cursor to "2 Write VFD" and press the
READ-key.
66
Description
Display
Writing the parameter settings is select-
ed, and the confirmation screen for writ-
ing execution is displayed.
1
MONITOR
2 PU Oper
3 Pr.List
Press the WRITE-key.
4 Pr.Clear
The parameter settings stored in the
FR-PU07 are copied to the copy desti-
nation inverter.
9 S/W
10 Selectop
Reset the inverter. (Refer to page 57).
11 Option
12
PRCpy set
Overwriting the data of the FR-PU07 deletes the previous data.
1
Copy area 1
Exercise care not to switch power off while parameters are being
2 Copy area 2
written.
3 Copy area 3
REMARKS
The parameter settings of three inverters can be stored in areas
Copy area 1
1 Read VFD
1 to 3.
2
Write VFD
Read and write cannot be stopped during execution.
3 Verifing
If power is switched off, parameter data stored in the parameter unit
remains unerased.
CAUTION
Display
012
Area 1 to VFD
WRITE:Executing
ESC:Cancel
Param Copy
Writing
Completed
Please Reset