2.3

Setting and Changing the Parameter Values

Using the FR-PU07 allows you to read the parameter of inverter or change the set value easily.
Refer to the inverter instruction manual for details of the parameters.

2.3.1 Specifying the parameter number to change the set value

Example: When changing 5 s to 180 s as the Pr. 8 "Deceleration
time setting"
Description
Press the PU-key.
The frequency setting screen appears
to switch to PU operation mode.
(You need not press the PU-key when
the parameter unit is already in the PU
operation mode.)
Press the PrSET-key.
The parameter unit enters the parame-
ter setting mode.
Enter the desired parameter number
"8".
Press the READ-key.
The current setting appears.
Description
Direct setting
Press "180".
Display
Enter the desired value.
Or
Freq Set
Step setting
SET
0.00Hz
Press the Cursor-keys ▲/▼. Display
"180" using the Cursor-keys ▲/▼.
0~400Hz
Press the WRITE-key.
SETTING MODE
The set value is changed.
0~9:Ser Pr.NO.
Select Oper
Press the SHIFT-key to display the next
SETTING MODE
parameter.
Pr.NO.
8
<READ>
If you entered an incorrect value, press the ESC-key to return to the
pre-entry state.
8 Dec.T1
5.0s
0~3600s
FUNCTIONS
Display
8 Dec.T1
5.0s
180s
0~3600s
2
8 Dec.T1
180.0s
Completed
9 Set THM
2.55A
0~500
21