Sample Event Capture; Application Examples - AEMC Simple Logger II User Manual

Hide thumbs Also See for Simple Logger II:
Table of Contents

Advertisement

4.9.1

Sample Event Capture

The above example assumes that the "Invert display polarity (event
displayed as a high)" is selected from the scales tab of the configuration
(default setting).
4.9.2

Application Examples

Rain Gauge:
Each time a tipping bucket fills and tips, a contact opens indicating that 0.1
inch of rain has filled the bucket. Attaching the L404 to this contact allows
recording of both the number of times the bucket has tipped, as well as the
totalization of rainfall during the recording.
In the configuration menu, the user has the ability to program both the
weight and value of an event pulse. In this case, the weight would be 0.1
and the units would be in inches.
In Figure 4-2, eight tips occurred for a total of 0.8 inches of rainfall.