MODEL
L322
ELECTRICAL
Channels
Two
Input
One 4-position removable screw-type terminal block
Input Level
-20mA
to +20mA
DC
DC
Accuracy
(0.25% of Reading +0.05mA)
Resolution
0.01mA
Maximum Input Current***
±24mA
DC
Input Impedance
50W
Sample Rate
Maximum of 8 samples taken at storage interval
Storage Rate
Programmable from 125ms to 1 per day
Storage Modes
Start/Stop, FIFO and Extended Recording Mode* (XRM
), Alarm
Recording Length
15 minutes to 8 weeks, programmable using DataView
®
Memory
240,000 measurement (512KB).
Recorded data is stored in non-volatile memory and
retained even if battery is low or removed.
Communication
USB 2.0 optically isolated
Power Source**
2x1.5V AA (LR6) alkaline batteries
Battery Life
100 hours to >45 days
(dependent on storage rate/recording length)
MECHANICAL
Dimensions
5.45 x 2.75 x 1.28" (136 x 70 x 32mm)
Weight (with battery)
6.4 oz (181g)
Case
UL94-V0
Vibration
IEC 68-2-6 (1.5mm, 10 to 55Hz)
Shock
IEC 68-2-27 (30G)
Drop
IEC 68-2-32 (1m)
ENVIRONMENTAL
Operating Temperature
14° to 122°F (-10° to 50°C)
Storage Temperature
-4° to 140°F (-20° to 60°C)
Relative Humidity
Up to 85% at 95°F (35°C), Non-condensing
Altitude
2000m
SAFETY & ELECTRO-MAGNETIC COMPATIBILITY
Safety Rating
EN 61010-1; 50V CAT III; Pollution Degree 2
Protection Degree
IP40
Electro-Magnetic
EN 61326-1; 07/1997 (+A1 10/1998, +A2 09/2001, +A3 05/2004)
Compatibility
CE Approved
Yes