3. Five LED Indicators
The LEDs on the instrument serve two functions: control operation
and status function.
• The control operation (function when holding down the PRESS
button) is indicated with text to the left of each LED.
• The status function (function when PRESS is not being held down)
associated with each LED is indicated with text to the right of each
LED.
• Refer to § 4.1 for detailed descriptions of each LED.
4. Female Type Mini-B USB Connector
5. Reset Switch (not shown)
The RESET switch resets the CPU. To access the switch, remove the
battery compartment cover. The switch is located at the top left of the
battery compartment (refer to § 4.11).
6. Flash Upgrade Switches (not shown)
These two switches (accessible from under the battery compartment),
the RESET switch and upgrade software are used to recover from a
failed flash upgrade procedure (refer to § 4.12).
WARNING: If the RESET switch is pressed when the logger is recording,
data in memory may be lost.