AEMC Simple Logger II User Manual page 16

Hide thumbs Also See for Simple Logger II:
Table of Contents

Advertisement

MODEL
ELECTRICAL
Channels
Input
Input Level
Accuracy
(50/60Hz)
Resolution
Maximum Input Current***
Input Impedance
Sample Rate
Storage Rate
Storage Modes
Recording Length
Memory
Communication
Fuse
Power Source**
Battery Life
MECHANICAL
Dimensions
Weight (with battery)
Case
Vibration
Shock
Drop
ENVIRONMENTAL
Operating Temperature
Storage Temperature
Relative Humidity
Altitude
SAFETY & ELECTRO-MAGNETIC COMPATIBILITY
Safety Rating
Protection Degree
Electro-Magnetic
Compatibility
CE Approved
Simple Logger
II Series
®
Two recessed banana jacks
0 to 10mA unspecified
10 to 50mA: ±(0.5% of Reading +1mA)
50 to 1000mA: ±(0.5% of Reading +0.5mA)
Programmable from 125ms to 1 per day
Start/Stop, FIFO and Extended Recording Mode* (XRM
15 minutes to 8 weeks, programmable using DataView
240,000 measurement (512kB).
Recorded data is stored in non-volatile memory and
retained even if battery is low or removed.
USB 2.0 optically isolated
2A FA 250V 5x20mm
2x1.5V AA (LR6) alkaline batteries
100 hours to >45 days
(dependent on storage rate/recording length)
5.18 x 2.75 x 1.28" (132 x 70 x 32mm)
IEC 68-2-6 (1.5mm, 10 to 55Hz)
14° to 122°F (-10° to 50°C)
-4° to 140°F (-20° to 60°C)
Up to 85% at 95°F (35°C), Non-condensing
EN 61010-1; 50V CAT III; Pollution Degree 2
EN 61326-1; 07/1997 (+A1 10/1998, +A2 09/2001, +A3 05/2004)
L111
One
0 to 1A
AC
0.1mA
1.2A
1W
64 samples/cycle
6.64 oz (188g)
UL94-V0
IEC 68-2-27 (30G)
IEC 68-2-32 (1m)
2000m
IP40
Yes
), Alarm
®
15

Advertisement

Table of Contents
loading

Table of Contents