Cannot set power levels. Power Level x invalid.
This occurs when setting the power level settings when the depth values do not increase as the power lev-
els increase. Check that every depth selection for each sequential power level is greater than the previous.
No Dongle Found In System. Please Plug Dongle In And Try Again.
This error can occur if the USB device has not been detected by windows or the Dongle is not connected
to the system. Remove the dongle if it is already in place and then reconnect it to the WASSP Processor af-
ter a few seconds. Press the retry button. The system will operate in replay mode without a WASSPDONGLE
but will not work in real time.
This dongle does not support the WMB-X230 system.
This error will occur if the current WASSP dongle is not licensed to run a WMB-X230 system. Contact your
dealer to acquire an appropriate WASSP dongle.
No License File Found On Dongle.
The most likely cause of this error is that the WASSP dongle has been modified or the contents have be-
come corrupted. If the license file has been removed from the dongle the system will not operate.
Contact your dealer to source a new WASSPDONGLE – you will need to return your current faulty Dongle.
License File Is Corrupted.
The licence file on the WASSPDONGLE has been modified in some way and is no longer valid. Contact your
dealer to source a new WASSPDONGLE – you will need to return your current faulty Dongle.
No Attitude: No Pitch.
The system is configured to compensate for Pitch and there has been a gap of multiple pings where there
was no Pitch data received. Check the Motion Sensor configuration in WASSP. Also check the Serial Port
configuration in the WASSP Transfer Task and finally that the sensor itself is on and operating correctly.
No Attitude: No Heave.
The system is configured to compensate for Heave and there has been a gap of multiple pings where there
was no Heave data received. Check the Motion Sensor configuration in WASSP. Also check the Serial Port
configuration in the WASSP Transfer Task and finally that the sensor itself is on and operating correctly.
No Attitude: No Roll.
The system is configured to compensate for Roll and there has been a gap of multiple pings where there
was no Roll data received. Check the Motion Sensor configuration in WASSP. Also check the Serial Port con-
figuration in the WASSP Transfer Task and finally that the sensor itself is on and operating correctly.
TX PWR ERROR
This warning informs the operator that the Transmitter did not reach full voltage during the system start up
sequence - the most common cause for this is a low 24V power supply voltage/current. If the system ap-
pears to operate correctly after you see this message then this is not an issue. If the system does not appear
to function then the error implies that the BTxR Transmitter unit has failed - Contact your Dealer for further
assistance.
System Initialisation Failure
This error implies that the system was not fully operational when the WASSP GUI was run. Shut down the
WASSP Processor and the BTxR and do a complete restart. If the error message continues to be shown,
refer to the troubleshooting section on Page 76, or contact your dealer for further assistance.
Doc. P/N:
WSP-009-008
Version:
V1.3
Issue Date:
April 2014