The System Has Stopped Transmitting Without Operator Intervention. Why; When I Click The Mode Button, Or Run A Replay (Demo) File I Get No Picture On The Display. Why; When I Press The Mode Button, The Button Goes Red And A Number On It Counts Up, But There Is No Activity On The Wassp Display. How Do I Fix This; What Does The Error Message That Appears When I Run Wassp Mean? Is My Wassp System Faulty - Wassp WMB-3230 Operator's Manual

Table of Contents

Advertisement

9.5
The system has stopped transmitting without operator intervention.
Why?
If time is taken from the system by another application for long enough, the WASSP system may
restart transmission in a number of seconds. If the system does not restart, try stopping and then
starting the system using the MODE button on the Main Menu. If this does not work, try to restart the
WASSP program and the BTxR. The most likely cause of this is a sudden power supply spike or drop.
9.6
When I click the MODE button, or run a replay (demo) file I get no
picture on the display. Why?
The WASSP program is designed to run in 32-bit colour, with a minimum 1024x768 resolution. Check
your display settings and change if required.
9.7
When I press the MODE button, the button goes red and a number on
it counts up, but there is no activity on the WASSP display. How do I fix
this?
First make the following checks of your WASSP installation:
Check that the BTxR power is ON and the LED light on the front panel has lit up either GREEN or RED.
Make sure the CAT5 network cable is connected at both the BTxR and the WASSP Processor ends
(unplug and re-plug to make sure).
Check that the Transfer Task application is running (look for the icon on the Start Bar at the bottom
of your monitor) and was running when you started WASSP. If not, restart WASSP after running the
Transfer Task application.
9.8
What does the error message that appears when I run WASSP mean? Is
my WASSP system faulty?
Consult the list below for the cause/course of action if an error message is displayed in WASSP.
Cannot Find Tide TCD File
Use the tide function to search for a valid database file.
Check file is present in directory. Reinstall if not present.
Error Loading TVG File
Check in the Windows Control Panel under Regional and Language Options,
Regional Options, Customize, Numbers Tab, that the "Decimal Symbol" setting is set to a '.' rather than a ','
(comma)
Check file is present in directory. Reinstall if unable to locate.
"Too Many Files With This Name. Aborted."
This occurs when storing raw data using the data recorder if there are more than 1000 files of the same ini-
tial name in a directory. Change the name or directory if you wish to continue to save raw data files. NOTE:
Unless you require the raw data for some purpose it is not recommended to record raw data files – these
files are very large (≈ 2Gb/hour) and will require careful management in order to prevent the Hard disk drive
of your WASSP Processor from becoming full. A WASSP Processor with a full disk drive becomes unusable.
Try to have at least 10 GB of free drive space at all times to allow sufficient room for system file manage-
ment.