2.3 Power Supply Troubleshooting
DC IN
1st Battery
2nd Battery
PORTEGE S100 Maintenance Manual (960-508)
Downloaded from LpManual.com Manuals
Error code
10h
AC Adaptor output voltage is over 16.5V.
11h
Common Dock voltage is over 16.5V.
12h
Current from the DC power supply is over 7.00A.
13h
Current from the DC power supply is over 0.5A when there is no load.
14h
Current sensing IC is not normal.
Error code
20h
Overvoltage is detected. (Not supported)
21h
Main battery charge current is over 7.00A.
22h
Main battery discharge current is over 3.9A when there is no load.
Main battery charge current is over 3.9A when AC adapter is not
23h
connected.
24h
Current sensing IC is not normal.
25h
Main battery charge current is over 0.3A.
Error code
30h
Overvoltage is detected. (Not supported)
31h
Secondary battery charge current is over 7.00A.
32h
Secondary battery discharge current is over 3.9A when there is no
load.
33h
Secondary battery charge current is over 3.9A when AC adapter is not
connected.
34h
Current sensing IC is not normal.
35h
Secondary battery charge current is over 0.3A.
2 Troubleshooting Procedures
Meaning
Meaning
Meaning
2-9