4 Replacement Procedure
4.29 Fluorescent Lamp
Fasten screws of the PCB and bezel
1. Fasten four screws shown in Figure 4-62.
N・
CAUTION: (1) The tightening torque must not exceed 0.176
m (1.8kgf
cm) for all the
screws. No loose fastening is allowed.
(2) For the Philips screwdrivers, use an insert bit of point size 0.
Insulation sheet
Screw
Screw
Screw
Screw
Figure 4-62 Replacing 14.1 Inch TMD fluorescent lamp (SXGA+) (10)