3.3 Check of the RAID configuration
3.3.3 Specification of the failed HDD
Check the RAID configuration condition from the
failed drive.
TOSHIBA RAID / RAID Information Display
Copyright(c) 2005 TOSHIBA CORPORATION. All Rights Reserved.
LD0 RAID-1
Port
0
1
< RAID : not OPTIMAL >
3.3.3.1 RAID : OPTIMAL
When RAID is "OPTIMAL" (Both the two drives are normal), it is judged that RAID
configuration is normal. There are the following reasons why the repair is requested.
Abnormal noise of the motor from the HDD:
Refer to the 2.5-HDD trouble shooting in Chapter 2, Troubleshooting Procedures.
Access to the HDD is very slow :
Display the drive log by using Independent Utility of the DIAGNOSTIC
PROGRAM. Check if ten or more continual logs of the message indicating retry
such as "Write Error occurred, Retry the command." or "Other Read Error occurred
are recorded in the drive log of either HDD. If recorded, the drive is failed and
should be repaired. Refer to Independent Utility in Appendix J.
In the other case above mentioned, it is judged that the MB side fails.
PORTEGE S100 Maintenance Manual (960-508)
Downloaded from LpManual.com Manuals
Level
Status
DEGRADE
Write cache
Degrade Bootup
MBR Protection
S.M.A.R.T
Assgn Status
LD0-0 ONLINE
LD0-1 FAILED
Capacity
xxGB
: Enable
: Yes
: Disable
: Enable
Size
Model
xxGB
FUJITSU-------------
xxGB
FUJITSU-------------
3 Tests and Diagnostics
shown below and specify a
Rev xx.xx.xxxx
Rev
xxxxxxx
xxxxxxx
3-13

Advertisement

Table of Contents
loading