Mira Gem 88 B - Built-in Shower Control
The built-in shower control is designed to be concealed into a solid or dry-lined wall
structure. A support bracket assembly (optional accessory) is available which can
be used to fix the shower control into a shower cubicle, laminated panel, stud partition
or dry partition wall.
The building-in depth (to the finished wall surface) is between 50 and 68 mm. The
building-in depth dictates how much of the flow and temperature control knob will be
visible through the concealing plate when the installation is completed.
A building-in shroud is supplied to protect the shower control during plastering and
tiling and provides a reference for the building-in depth when chasing out the wall.
The shower control is not supplied with any interconnecting pipework or plumbing
fittings. Inlet and outlet threads are 1/2" BSP female parallel.
The Mira Gem 88 is supplied with inlet connections hot left, cold right and bottom
outlet as standard.
1. Solid or dry-lined wall structures
1.1 Make a recess in the wall large enough
for the shower control, pipework and
plumbing connections.
Make sure that the building-in depth is
correct.
1.2 Remove the plastic building-in shroud.
The two building-in shroud retaining
screws should be screwed temporarily
into the base for use later.
Note! Do not remove the Body
Shroud or Seal. If the cavity seal or
shroud have been removed or are
incorrectly fitted, refer to section:
'Refitting the Cavity Seal'.
Backplate
(Make sure is fitted level to the wall)
Cavity
Seal
45°
22
Body Shroud
Building-in
Shroud
Retaining
Screws