Mira Platinum Installation And User Manual

Digital shower
Hide thumbs Also See for Platinum:

Advertisement

Quick Links

Mira Platinum
Digital Shower
1514415-W2-A
Installation and User Guide
Please leave these instructions with the user

Advertisement

Table of Contents
loading

Summary of Contents for Mira Platinum

  • Page 1 Mira Platinum Digital Shower 1514415-W2-A Installation and User Guide Please leave these instructions with the user...
  • Page 2: Table Of Contents

    Thank you for purchasing a Mira Platinum. You must read this guide thoroughly, and having done so, keep it handy for future reference. For step-by-step installation videos, datasheets or spares information, please visit the Mira Showers website. Contents Important Safety Information...
  • Page 3: Important Safety Information

    Important Safety Information Products manufactured by Kohler Mira Ltd. are designed to be safe, provided that they are installed, used and maintained in good working order, in accordance with our instructions and recommendations. Follow all warnings, cautions and instructions contained in this guide, and on, or inside the product.
  • Page 4 9. DO NOT perform any unspecified modifications, drill or cut holes in the product other than instructed by this guide. When servicing only use genuine Kohler Mira replacement parts. 10. If the product is dismantled during installation or servicing then, upon completion, an inspection must be made to ensure all electrical connections are secure and that there are no leaks.
  • Page 5 15. This product can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning the use of the appliance in a safe way and understand the hazards involved.
  • Page 6 30. Warning! Never remotely operate or alter any of the Mira Platinum shower settings if it is already occupied/being used by another person or you are not within the vicinity of the outlet.
  • Page 7: Pack Contents

    Pack Contents Digital Mixing Valve High Pressure/Combi 2 x Push-Fit Isolators (15mm Pipework Only) 1 or 2 x Outlet Connector (Depending on number of outlets) Digital Mixing Valve 3 x Fixing Screws 3 x Wall Plugs 2 x Pozi Screws (3.5 x 12mm) 1 x Power Supply 2 x Fixing Feet...
  • Page 8 Ceiling Fed Shower Fitting 1 x Plastic Pipe 1 x Ceiling Plate 2 x Brackets 1 x Elbow 1 x Showerhead 1 x Chrome Supply Tube 2 x Spacers 1 x Slide Bar Assembly 1 x Hose 1 x Installation Template 2 x Rubber Washers 1 x Hex Key...
  • Page 9 Rear Fed Shower Fitting 2 x End Plugs 2 x Brackets 1 x Showerhead 1 x Hose 2 x Rubber Washers 1 x Slide Bar Assembly 1 x Hex Key 1 x Right Angled 2 x 45 mm Screws Connector (RAC) Kit 2 x Wall Plugs 2 x Hex Screws 1 x Installation Template...
  • Page 10 Ceiling Overhead Fitting Kit (Dual Outlet models only) 1 x Nut 2 x Wall Plugs 1 x Olive 1 x Ceiling Mount Plate 2 x Hex Screws 1 x Ceiling Plate 1 x Chrome Supply Tube 1 x Brazed Pipe 1 x Signature Overhead...
  • Page 11 Rear Fed Overhead Fitting Kit (Dual Outlet models only) 1 x Concealing Shroud 1 x Shower Arm 1 x Backplate Assembly 1 x Fittings Pack 1 x Signature Overhead User Controller 1 x Charging Cable 1 x User Controller...
  • Page 12: Guarantee

    Guarantee The Mira Platinum has been designed for domestic use only, it is not recommended for Commercial or Healthcare use. For domestic installations, Kohler Mira Ltd. guarantee the Mira Platinum against any defect in materials or workmanship for a period of five years from the date of purchase (shower fittings for one year). For non-domestic installations, Kohler Mira Ltd. guarantee the Mira Platinum against any defect in materials or workmanship for a period of one year from the date of purchase.
  • Page 13: Specifications

    The Bluetooth word mark and logos are registered trademarks owned by the ® Bluetooth SIG, Inc. and any use of such marks by Kohler Mira Ltd is under license. Other trademarks and trade names are those of their respective owners. General...
  • Page 14 1 bar maintained pressure* Default flow rate target: 12 L/min Maximum settable flow rate target: 16 L/min Mira Digital Mixing Valve Pumped/Gravity (not suitable for mains pressure systems) Caution! The pump in this product is not suitable for dry running. It is essential you follow the commissioning sequence detail in this guide.
  • Page 15 *Note: Maintained (or dynamic) pressure is the pressure at the valve inlets during operation. Some installations will see a significant pressure drop in the supply pipework when water is flowing, especially when long plastic pipework and small bore fittings are used. It is recommended to keep supply pipework as short as possible, avoid unnecessary bends and minimise the number of fittings that are used. For longer pipe runs, it may be necessary to increase the nominal pipe size to reduce the pressure drop. Consult a plumbing professional if you are unsure.
  • Page 16: Suitable Plumbing Installations

    Suitable Plumbing Installations Digital Mixing Valve (High Pressure/Combi Models) 1. Combination boiler systems - the digital high pressure/combi shower can be installed with an instantaneous combination boiler. 2. Unvented mains pressurised system - the digital high pressure/combi shower can be installed with an unvented, stored hot water cylinder system.
  • Page 17 Digital Mixing Valve (Pumped/Gravity Models) Gravity fed hot water systems Caution! Digital pumped/gravity valves must never be plumbed to mains pressure systems. This includes mixed gravity fed and mains pressure e.g. gravity hot and mains cold. Doing so will invalidate the warranty and potentially cause product and property damage.
  • Page 18: Showering Maximum Flow Rate

    Alternatively reduce the outlet flow by decreasing the flow rate with the user controller. *Note: If your water system is not capable of delivering minimum maintained pressure at the valve inlets, you will not be able to achieve the maximum flow rate from your shower even if adjusted via the Mira Showers app. Ensure you have the minimum required maintained pressure at the valve inlets before installation.
  • Page 19: Installation Schematic

    Installation Schematic Refer to page 23 for controller placement. Refer to page 23 for controller placement. Rear Fed Ceiling Fed Products Products...
  • Page 20: General Installation

    General Installation All installations shall comply with the Water Supply (Water Fittings) Regulations 1999, Water Supply (Water Fittings) Regulations (Northern Ireland) 2009, and The Water Supply (Water Fittings) (Scotland) Byelaws 2014. Safe and easy access to the product should be available at all times. When installing the product in an area not regularly accessed, consideration for potential leaks must be taken into account.
  • Page 21: Installation Digital Mixing Valve

    • Supply pipework layout must be arranged to minimize the effect of other outlet usage as shared water supplies may reduce its flow performance upon the dynamic pressures at the digital mixing valve inlets. • Avoid installations where air locking could occur. • Cold water cisterns should hold no less than 230 litres and hot water cylinders no less than 210 litres (gravity system only). • To eliminate pipe debris it is essential that water supply pipes must be flushed prior to connecting the digital mixing valve to the system so debris cannot enter the digital mixing valve internals.
  • Page 22 • DO NOT use foil type loft insulation as this will inhibit Bluetooth and Wi-Fi signals, which will degrade the communication range between the digital valve, the user interface, and Mira app. • DO NOT insulate the Power Supply Unit (PSU).
  • Page 23 Fit the 2 feet in desired location on digital mixing valve using the two Pozi 3.5 x 12mm screws supplied. Note: There are 4 possible locations to install the feet, depending on your installation constraints. Position and Signal Test N o t e: Va l v e r e q u i r e s w i f i connection for App connection, Hot Water Inlet...
  • Page 24 If you are unable to position the controller and Valve in locations where they can communicate please acquire the Mira “Bluetooth adapter”. Refer to page 60 for accessories. Caution! The given wireless range concerns use in the open area, in ideal conditions without any natural or artificial obstacles.
  • Page 25 Place user controller in approximate final position (no more than 5m recommended (Max 10m) from digital mixing valve) and press any button to wake the user controller. Press the ‘Pair’ button on user controller to start the pairing process. UI is not connected to valve. Please move UI within range or pair with valve.
  • Page 26 Mark the fixing holes in the required positions and secure using suitable fixings. Note: The valve must be installed on a flat surface. Mounting on a Horizontal Surface Mounting on a Vertical Surface Connect the hot and cold inlet supply pipework to the digital mixing valve. Note: DO NOT use any type of jointing paste or compound on any pipework or fittings supplying the digital shower valve. These can build up within the product and reduce the performance or cause early failure.
  • Page 27 Outlet 1 - Inlet Handset Outlet 2 - Push-fit Isolators Overhead / Bathfiller fitted to both Inlets Cold Inlet Push-fit connector to the shower outlets After installing the valve, check the push-fit connectors are correctly engaged. a. Ensure every pipe is fully pushed into the internal stop. b. Pull the pipework to ensure it is retained and locked in place. c.
  • Page 28: Ceiling Fed Shower Fittings

    Installation: Ceiling Fed Shower Fittings Fix at convenient height for all the family. Position the fittings so that water sprays down the centre of the bath, or away from the opening of a shower cubicle. Water should spray away from the user controller when the handshower is held on the slide bar. Optional spacers Decide on suitable position for slide (supplied) bar avoiding buried cables and pipes in both wall and ceiling.
  • Page 29 Drill into the marked holes to suit the wall fixings. Insert the wall plugs. Insert fixing screws through holes in wall brackets and fix to the wall. DO NOT fully tighten. Caution! Be aware of hidden pipes or cables. Use template to set correct distances between the wall brackets.
  • Page 30 Fit the slide bar assembly over the wall brackets and secure with screws supplied. DO NOT overtighten. Connect the ceiling chrome supply tube. Feed the plastic pipe up through the slide bar and chrome supply tube into the ceiling. DO NOT allow any debris to block the plastic pipe.
  • Page 31 Connect elbow to digital mixing valve. Note: When shortening pipework for use with any push-fit fitting, follow manufacturer’s guidelines for finishing and cleaning the pipe. Elbow Supplied Fit the shower hose to the end of the slide bar assembly. Ensure the washer is in place in both ends of the hose. Caution! DO NOT fit the handset after pipework has been fully flushed through.
  • Page 32: Rear Fed Shower Fittings

    Installation: Rear Fed Shower Fittings Fit an isolating valve (not supplied) close to the digital mixing valve for ease of maintenance. Make sure that the outlet pipe work protrudes approx. 60 mm through a Dia 20 mm hole square to the finish wall surface. Note: To be trimmed after completion 60mm of finished wall surface when installing right angled connector.
  • Page 33 Secure the backplate to the wall so the Foam Seal foam seal is fully compressed. I m p o r t a n t ! E n s u r e a r r o w o n backplate is oriented vertical as shown.
  • Page 34 Check for leaks. Fit the cover. Carefully lift the cover to locate the screw. Unscrew fully to lock using the 2.5 mm hex key supplied. The slide bar should be fixed to the wall at a convenient height for all the users. It should be positioned so that water sprays down the centre of the bath, or away from the opening of a shower cubicle.
  • Page 35 Drill into the marked holes to suit the Use template to set correct distances wall fixings. Insert the wall plugs. between wall brackets. Fully tighten screws. Insert fixing screws through holes in wall brackets and fix to wall. DO NOT Note: Slots in wall brackets allow for fully tighten at this stage. adjustment. Use one horizontal slot and one vertical slot.
  • Page 36 Fit the one end of the shower Fit the slide bar end caps into top hose to the right angled connector and bottom of the slide bar assembly. assembly and another end to the Push and twist caps until they “click” handset.
  • Page 37: Deluge Overhead

    Installation: Deluge Overhead Rear Fed The shower arm and deluge head should be fitted at a convenient height for all the family. It should be positioned so that water sprays down over the centre of the bath, or away from the opening of a shower cubicle. The outlet pipe must protrude 18 mm (± 2 mm) from the finished wall surface and a minimum 35 mm from the ceiling. Note: Cut the pipe to the correct length and remove any burrs.
  • Page 38 Fit the olive and compression nipple Fit the concealing shroud onto the over the outlet pipe and tighten the shower arm. compression nipple to 25 ± 1Nm. Fit the compression nut and olive onto the shower arm. Backplate Fit the shower arm into the compression nipple and tighten the compression nut Compression Nipple to 25 ±...
  • Page 39 Ceiling Fed The deluge head should be fixed to the ceiling at a convenient height for all the family. It should be positioned so that water sprays down over the centre of the bath, or away from the opening of a shower cubicle. The fitting of the deluge head into the ceiling will be easier with the aid of a helper. When you are working within the bath or shower tray area use a towel or blanket to protect the surface from damage.
  • Page 40 Centralise the brazed pipe in the hole then screw the ceiling mount plate to the wooden support. Offer the deluge head to the brazed pipe and determine the showering 75 mm height required. Push / pull the brazed pipe using a twisting motion to adjust the height. Check the height is correct and use Determine a 15 mm pipe cutter to cut the pipe to...
  • Page 41 Push the cut end of the chrome supply tube into the concealing plate then slide the chrome supply tube over the threaded end of the brazed pipe and up through the hole until the concealing plate is secured in the hole and the concealing plate is flat against the Ceiling Plate...
  • Page 42: User Controller

    Caution! Avoid drilling through buried cables or pipes. Make sure surface is clean and dry. Fix the cradle to finished wall surface. Note: Use silicone sealant around wall fixing screws to prevent water ingress. Hook the user controller on top of the Press the Mira showers logo to wake cradle and push into place. up the user controller and check that the connection with the valve is still Warning! This appliance contains in place.
  • Page 43: Commissioning

    Commissioning (High Pressure Product) Warning! For the Pumped low pressure valve you must follow the separate valve commissioning sequence on page 44. Turn on the water supply and open water inlet supply isolators. Turn on the electrical supply to digital mixing valve. The digital mixing valve will power and perform a self check where the LED will indicate a RED light initially and will then change to BLUE light after a few seconds.
  • Page 44 Ensure supplies are correctly plumbed, are on & tanks full. Ensure handset is removed, hose dropped & directed to waste. Note: The Mira Wireless Remote Accessory will not operate until commissioning has been completed. Turn on the water supply and open water inlet supply isolators.
  • Page 45 Turn on the electrical supply to digital mixing valve. The digital mixing valve will power and perform a self check where the LED will indicate a RED light initially and will then change to a BLUE/RED flashing light after a few seconds. Note: If the LED does not turn to a BLUE/RED flashing light after 10 seconds, indicating the product is ready to commission, refer to the troubleshooting or fault diagnosis section.
  • Page 46 Please check inlet pipework and retry. Failures can be caused by partially opened isolators or airlocks. Please check Commissioning inlet pipework cancelled and retry Retry Retry Recommissioning. If recommissioning is required at any point in the future, this can be completed using the Mira Showers app or settings menu on the controller.
  • Page 47: Using The Controller

    Using the Controller Start the shower by pressing the outlet Adjust the temperature by rotating icon buttons. the bezel . Note: On a dual outlet product, both Clockwise - Increases the temperature outlets can run at the same time but Anti-clockwise - Decreases the flow will be shared.
  • Page 48: User Controller: Features

    Press ‘Select’ to choose the desired preset. Press the ‘Start’ button to activate the You can scroll forward to ‘Exit’ and preset outlet(s), temperature, flow level press ‘Select’ or the ‘Mira logo’ to return and shower duration. to the main menu. s e t : 3 0...
  • Page 49 ‘Select’. Selecting ‘Exit’ at the l e c end of the items or pressing the ‘Mira logo’ will return to the main menu.
  • Page 50 Setting Description Variables High pressure valve - 4-16 lpm. See page 13. Maximum Flow Sets maximum flow rate Pumped for gravity valve - 6-16 lpm. See page 14. High pressure valve - 4-16 lpm. See page 13. Minimum Flow Sets minimum flow rate Pumped for Gravity valve - 6-16 lpm.
  • Page 51 Charging the User controller The user controller screen will indicate if charging is required at the end of a shower Note: by showing the following screens. Only charge the controller when prompted to ensure battery longevity. Recharge battery litre Exit Ensure the shower is OFF and remove In a dry environment carefully pull out the controller by lifting the bottom...
  • Page 52: Set Up: Mobile App

    Mira Showers app is kept up to date with the latest bug fixes and performance enhancements. Your shower can be set up either by using the controller or via the Mira Showers app. See “Position and Signal Test” section on page 23.
  • Page 53 Once the Mira Showers app has been installed, open the app on your device and follow the on-screen instructions to connect your phone to your Digital Mixing Valve. You can then use the Mira Showers app to customise and control your Digital Mixing Valve remotely.
  • Page 54: Set Up: Wifi Connection

    Mira Platinum. It is the homeowner’s responsibility to ensure that no accidental operation (either via the app or connected smart speakers) will result in flooding as a consequence of this.
  • Page 55: Fault Diagnosis

    To access these advanced diagnostics features, please download the Mira Showers app (see section “Set Up: Mobile App”). Please follow this self-diagnosis section to be sure the product is at fault before contacting Mira. Diagnosis stage 1 (Error code check): In the first instance, check your product has no error warning displayed on the controller.
  • Page 56 Mira Showers app or using the controller menu option. Refer to diagnosis section 4b. Flow has been detected when the product should be off. Try powering off the product for 30 seconds or resetting in the Mira Showers app or using the controller menu option. Refer to diagnosis section 4c. Unusually high flow has been detected. Try powering off the product for 30 seconds or resetting in the Mira Showers app or using the controller menu option.
  • Page 57 3. Check the circuit breaker or RCD in your consumer unit has not tripped. 4. Check the fuse and replace if necessary (3 Amp). 5. Contact Mira Customer Service Team if none of the above restored power to the digital mixing valve.
  • Page 58 2. Check to see if you have a maximum showering duration set. This is designed to turn off the shower after a pre-determined duration. 3. Check to see if you are using pre-defined showering experiences. These may turn off the shower after a pre-determined duration. 4. The shower is designed to turn off after 30 minutes. 5. Use the Mira Showers app to check the error log. The shower is designed to turn off if the outlet temperature is too high.
  • Page 59 7. If none of the above resolved the issue, contact Mira Customer Service Team. 4e - Noise: 1. Pumped digital mixing valves can get air locked if not installed in accordance with the instructions in this guide and may exhibit outlet flow fluctuations and a high pitch “squealing”...
  • Page 60: Accessories

    Accessories Product Product Code Mira Wireless Remote Accessory 2.1903.098 Mira Bluetooth Extension Adapter GP148955W Wifi Extension Cable 1335278 Cleaning and Maintenance Always read the IMPORTANT SAFETY INFORMATION for your shower. Cleaning the showerhead Many household and commercial cleaners, including hand and surface cleaning wipes contain abrasives and chemical substances that can damage plastics, plating and printing and should not be used. These finishes should be cleaned with a mild washing up detergent...
  • Page 61 Replace/Clean the Check Valves/Filters Read the section “Important Safety Information” first. Before replacing any parts, ensure that the underlying cause of the malfunction has been identified. If the digital mixing valve is dismantled during installation or servicing then upon completion the product must be inspected to ensure there are no leaks. Warning! There are no user serviceable components beneath the cover of the appliance.
  • Page 62 Frequency Bands and Maximum Radio Frequency Power Hereby, Kohler Mira Ltd. declares that the radio equipment type Mira Platinum is in compliance with EU Directive 2014/53/EU & UK S.I. 2017/1206. The full text of the EU & UKCA declaration of conformity is available at the following internet address: www.mirashowers.co.uk...
  • Page 63 Notes...
  • Page 64: Customer Service

    Eire ● Products purchased ex-showroom display. T: 01 531 9337 ● Disinfection or descaling to reduce bacterial E: customerserviceeire@mirashowers.com growth or contamination. www.mirashowers.ie Mira is a registered trade mark Registered Office: EU Importer address: of Kohler Mira Limited. Cromwell Road, Kohler France S.A.S. Cheltenham,...

Table of Contents