  • Page 1 Mira Advance THERMOSTATIC ELECTRIC SHOWER 8.7 and 9.8 kW These instructions must be left with the user User Guide 1306246-W5-A...
  • Page 2: Safety Information

    Introduction Thank you for purchasing a quality Mira product. To enjoy the full potential of your new product, please take time to read this guide thoroughly, having done so, keep it handy for future reference. Guarantee For domestic installations, Mira Showers guarantee the...
  • Page 3 WARNING! TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR INJURY: 1. Installation of the shower must be carried out by qualified, competent personnel. Installers please read installation instructions before installing the shower. 2. The shower must be operated and maintained in accordance with the requirements of this guide.
  • Page 4 10. DO NOT connect the outlet of the shower to any tap, control valve, trigger handset or other device intended to restrict the water outlet flow. Fit only the Kohler Mira showerhead as supplied with this product, only Kohler Mira recommended accessories must be used.
  • Page 5: Using The Shower

    Using the Shower Each time the shower is operated it will confirm its status during the start-up process, confirming the mode setting and when the temperature is reached. Note! Further temperature adjustments during showering will not confirm temperature has been reached. Standard Mode When starting in standard mode the product will beep once when the start/stop button is pressed and the amber...
  • Page 6: Operating The Shower

    Operating the Shower Read the section: 'Safety Information' first. With the electrical supply turned on, press Start/Stop. Adjust the temperature and allow approximately 30 seconds for any temperature adjustments to reach the showerhead. The start/stop and status lights will pulse while getting up to temperature and the shower will beep once temperature reached.
  • Page 7 Press Start/Stop to shut down the shower. The pulsing start/ stop light and "beep" indicates that the shower is shutting down. Important! DO NOT isolate the power to the shower. The shower will purge water from its tank for a few seconds. Important! DO NOT isolate the power to the shower.
  • Page 8 In BEAB mode (3 beeps when start/stop button pressed) Set for max 41°C (see BEAB mode 'Using your shower') If your shower is not hot enough please contact your installer before calling Kohler Mira Shower Flow Performance Priority for the shower is to keep the showering temperature constant.
  • Page 9 Warning! There are no user serviceable components beneath the cover of the shower. Only a competent tradesperson should remove the front cover. We recommend any maintenance work is carried out by a Mira service Engineer or similarly qualified tradesperson. Reset the Shower This is the first solution to the shower not operating (See below).
  • Page 10 15 secs Restore power to the shower. The shower may "beep" and the Start/Stop button should illuminate. Operate the shower, refer to section: 'Using the Shower'. If the shower is linked to a Whale Instant Match Shower Drain Pump, check there is power to the pump. If the failure continues after resetting, there are a few basic supply checks that can be performed.
  • Page 11 Basic Supply Checks • Check there is electricity still supplied to the appliance (lights and/or beeps will confirm this). If in any doubt, contact a qualified electrician. If a short power cut has occurred during use, the shower will automatically reset and be ready when the white start/stop light is illuminated.
  • Page 12 Error Codes Status Start/Stop Error Possible Cause Indication Indication Code Rectification No Water Flow Flashing Flashing 1. Check isolator valves are fully open. 2. Check that the hose /showerhead is not blocked. 3. Isolate the electrical supply at the pull cord for a few seconds, turn the shower to full cold position,then re-apply...
  • Page 13 There are a number of other Error Codes with different light sequences. However, these are not user repair error codes and you should contact your installer or refer to the Support Section on the Kohler Mira website, www.mirashowers.co.uk. 1306246-W5-A...
  • Page 14: User Maintenance

    User Maintenance Cleaning Many household cleaners contain abrasives and chemical substances, and should not be used for cleaning plated or plastic fittings. These finishes should be cleaned with a mild washing up detergent or soap solution, and then wiped dry using a soft cloth.
  • Page 15 Notes 1306246-W5-A...
  • Page 16: Customer Service

    Servicing must only be undertaken by us or our Spares and Accessories appointed representative. We hold the largest stocks of genuine Mira Note! If a service visit is required the product must spares and accessories.Contact us for a be fully installed and connected to services.