Mira Gem 88 Installation & User Manual page 31

Shower control
Table of Contents

Advertisement

5.
Place the cavity seal and the cartridge
assembly on a flat surface.
6.
Align the cut-outs on the shroud with
the screw positions on the cartridge.
Push down firmly on the shroud while
lifting the edge of the cavity seal over
the lip of the shroud.
Note! A wet soapy solution applied
around the edge of the cavity seal will
aid location.
7.
Note the raised locating feature on the
cartridge, align this feature as shown
with the recessed feature in the brass
body. Push the cartridge firmly into
position.
Caution! If the cartridge is not
positioned correctly the shower will
leak from the body when the water
supply is turned on.
8.
Secure the cartridge into position with
the two cross head screws.
Caution! Do not overtighten the
screws as you may damage internal
components.
Screw Position
Cavity Seal
Raised
Locating
Feature
31
Screw Position
Apply a wet
soapy solution
before locating
shroud
Cavity Seal
Recessed Feature
Shroud
Cut-Out
Shroud
Pipe
Recess

Hide quick links:

Advertisement

Table of Contents
loading