Wiring the Regulator Board Terminal Strip
Table 7.6 – Snubber Resistor Braking Connections (Terminals 26 and 27)
Terminal #
26
Snubber Resistor Braking Signal
27
+24 VDC Common
Notes: These terminals are used with older Snubber Resistor Braking kits that require a
gate turn-on signal from the drive (for example, the M/N 2DB2010 series).
Table 7.7 – Status Relay Connections (Terminals 28-31)
Terminal #
N.C. Relay Contact
28
N.C. Relay Common
29
N.O. Relay Contact
30
31
N.O. Relay Common
Notes: Relay contact closure is programmable through parameter P.013. Refer to the
GV3000/SE Software Start-Up and Reference manual for more information.
Signal
Signal