Keypad/Display; Jumpers On Base Board (Pisc-40); Figure 2.8 - Keypad/Display; Table 2.2 - Settings Of Jumpers On Base Board - Reliance electric GV3000/SE Installation Manual

30 - 100 hp, 230v ac
Table of Contents

Advertisement

2.4.6 Keypad/Display

2.5 Jumpers on Base Board (PISC-40)

About the Drive
The front panel keypad/display is used to program and operate the GV3000/SE
drive. See figure 2.8. Refer to the GV3000/SE Software Start-Up and Reference
manual for more information.
Monitor Mode
LEDs
Password LED
Jumpers JP1 through JP4 on the Base board (PISC-40) are used for selection of
current feedback gain as shown in table 2.2. On the Base board, there is another
jumper, JP6, to be used for selection of ON/OFF level of precharge relay. Table 2.2
also shows the factory settings of these jumpers. For the locations of these jumpers,
see figure 2.9.
Jumpers
JP1
These jumpers are used for selection of
(for U-phase)
current feedback gain as follows:
JP2
A:
(for V-phase)
B:
JP3
(for bus current)
JP4
(for bus current)
JP6
This jumper is used for selection of ON/OFF
level of precharge relay as follows:
A: ON at 175 V, OFF at 155 V
B: ON at 220 V, OFF at 200 V
Drive Status LEDs
Display
.
SPEED
VOLTS
AMPS
Hz
Kw
TORQUE
Password
STOP
RESET
Stop / Reset
Key

Figure 2.8 - Keypad/Display

Table 2.2 - Settings of Jumpers on Base Board

Description
for 30 to 50 HP units
for 60 to 100 HP units
Keypad
£
¥
AUTO
Forward
RUNNING
MAN
Reverse
REMOTE
JOG
RUN
PROGRAM
AUTO
JOG
FORWARD
REVERSE
PROGRAM
ENTER
START
Start Key
Factory Setting
For 30 to 50 HP units:
:
A
For 60 to 100 HP
units: B
Set to A position
2-11

Advertisement

Table of Contents
loading

Table of Contents