Grounding Information

This dryer must be grounded. In the event of malfunction or
breakdown, grounding will reduce the risk of electric shock by
providing a path of least resistance for electric current. The dryer
is equipped with a cord having an equipment-grounding conduc-
tor and a 3 prong grounding plug. The three-prong grounding
plug on the power cord should be plugged directly into a polar-
ized three-slot effectively grounded receptacle rated 110/120
Volts AC (alternating current) 15 Amps.
WARNING
This dryer is equipped with a three-prong (ground-
ing) plug for your protection against shock hazard
and should be plugged directly into a properly
grounded three-prong receptacle. Do not cut or re-
move the grounding prong from this plug.
WARNING
Improper connection of the equipment-grounding
conductor can result in a risk of electric shock.
Check with a qualified electrician or service person if
you are in doubt as to whether the dryer is properly
grounded.
Do not modify the plug provided with the dryer - if it will not fit
the outlet, have a proper outlet installed by a qualified electrician.
NOTE: Have a qualified electrician check the polarity of
the wall receptacle. If a voltage reading is measured
other than that listed on the dryer's nameplate, the
qualified electrician should correct the problem.
Do not operate other appliances on the same circuit when this ap-
pliance is operating.
WARNING
To reduce the risk of an electric shock or fire, DO
NOT use an extension cord or an adapter to connect
the dryer to the electrical power source.
20
W036
W038
W037
©
Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT
Plug cord into separately fused 15 Amp circuit.
2
1
8
7
1. "L1"
2. Ground
3. Neutral
4. Neutral Side
5. Round Grounding Prong
6. 0 V.A.C.
7. 120±12 V.A.C.
8. 120±12 V.A.C.
Figure 27

Recheck Steps

Refer to Installer Checklist on the back cover of this manual and
make sure that dryer is installed correctly.

Check Heat Source

Electric Dryers

1. Close the loading door and start the dryer in a heat setting (re-
fer to the operation instructions).
2. After the dryer has operated for three minutes, the exhaust air
or exhaust pipe should be warm.

Gas Dryers

1. To view the burner flame, remove the lower front panel of the
dryer.
3
6
4
5
DRY2022N_SVG