Troubleshooting/Faqs; Troubleshooting Guide - Siemens SITRANS F MAG 6000 I Operating Instructions Manual

Electromagnetic flowmeters
Hide thumbs Also See for SITRANS F MAG 6000 I:
Table of Contents

Advertisement

Troubleshooting/FAQs

10.1

Troubleshooting guide

Symptom
Output
signals
Empty display
Minimum
No flow signal
Minimum
Undefined
Indicates flow with no
Undefined
flow in pipe
Unstable flow signal
Unstable
Measuring error
Undefined
MAG 6000 I / MAG 6000 I Ex de transmitter
Operating Instructions, 04/2016, A5E02083319-AG
Error
Cause
code
1. No power supply
2. MAG 5000/6000/6000 I
defective
1. Current output disabled
2. Digital output disabled
3. Reverse flow direction
F70
Incorrect or no coil current
W31
Measuring pipe empty
F60
Internal error
P42
1. No load on current output
2. MAG 5000/6000/6000 I
defective
P41
Initializing error
Measuring pipe empty
Empty pipe cut-off is OFF
Electrode connection miss-
ing/electrode cable is insuffi-
ciently screened
1. Pulsating flow
2. Conductivity of medium too low Use special electrode cable
3. Electrical noise potential
between medium and sensor
4. Air bubbles in medium
5. High concentration of particles
or fibres
Incorrect installation
P40
No SENSORPROM
P44
CT SENSORPROM
F61
Defective SENSORPROM
F62
Wrong type of
SENSORPROM
F63
Defective SENSORPROM
F71
Loss of internal data
Remedy
Power supply
Check MAG 5000/6000/6000 I for
bended pins on the connector
Replace MAG 5000/6000/6000 I
Turn on current output
Turn on digital output
Change direction
Check cables/connections
Ensure that the measuring pipe is full
Replace MAG 5000/6000/6000 I
Check cables/connections
Replace MAG 5000/6000/6000 I
Switch off MAG 5000/6000/6000 I,
wait 5 sec. and switch on again
Select empty pipe cut-off
Ensure that the measuring pipe is full
Ensure that electrode cable is con-
nected and sufficiently screened
Increase time constant
Ensure sufficient potential equalizati-
on
Ensure medium does not contain air
bubbles
Increase time constant
Check installation
unit
Install SENSORPROM
®
unit
Replace SENSORPROM
®
reset SENSORPROM
CT transmitter
unit
Replace SENSORPROM
®
Replace SENSORPROM
unit
®
unit
Replace SENSORPROM
®
Replace MAG 5000/6000/6000 I
10
unit
®
unit or
®
unit with MAG
®
unit
®
unit
®
unit
®
59

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sitrans f mag 6000 ex de

Table of Contents