8.2.5.3

Technical data of the brake relay?

Input voltage
Input current
Max. connection cross-section:
Degree of protection
Switching capability of the NO
contact
Output voltage
Output current
External, controlled power supply required. Recommended voltage: 26 VDC
1)
8.2.5.4

Mounting and connecting the brake relay

Installing the Brake Relay
● FSA ... FSC: Install the Brake Relay next to the Power Module.
● FSD ... FSF: Install the Brake Relay at the rear of the lower shield plate. Attach the Brake
Relay before you install the shield plate.
Connecting the Brake Relay to the inverter
The connector for the Brake Relay is located at the front of the Power Module. Lay the cable
harness for the Brake Relay in the cable routing.
Power Module PM240-2
Hardware Installation Manual, 12/2015, A5E33294624B AD
Brake Relay
6SL32520BB000AA0
via the Power Module
via the Power Module
2.5 mm²
IP20
1-phase 440 VAC, 3.5 A
1-phase 30 VDC, 12 A
-
-
Spare parts and accessories
8.2 Optional accessories
Safe Brake Relay
6SL32520BB010AA0
20.4 ... 28.8 VDC
1)
Max. 2.5 A
2.5 mm²
IP20
-
24 V
max. 2 A