Dimension Drawings And Drilling Dimensions For Pt Power Modules - Siemens PM240-2 Hardware Installation Manual

Sinamics g120 built-in unit power module
Table of Contents

Advertisement

Installing/mounting
4.3 Mounting the Power Modules
Note
Brake relay
If you are using a brake relay to control a motor brake, then mount the brake relay at the rear
of the lower shield plate before you attach the shield module to the inverter. See also
Mounting and connecting the brake relay (Page 117)
If you are using an inverter with integrated line filter, then you must mount the shield module
as described below.
Procedure
Proceed as follows to mount the shield module:
1. Attach the EMC connecting bracket to the shield plate
2. Screw the shield module to the inverter
You have correctly mounted the shield module.
4.3.5

Dimension drawings and drilling dimensions for PT Power Modules

Table 4- 3
Frame size
FSA
FSB
FSC
The Power Modules can be mounted side-by-side. For tolerance reasons, we recommend a lateral
1)
clearance of 1 mm.
Wall thickness of the control cabinet ≤ 3.5 mm
2)
32
Mounting dimensions
Width
Height (mm)
1)
(mm)
126
238
154
345
200
411
.
using three screws, as shown in the diagram.
Depth
(mm)
2)
with shield
plate
322
171
430
171
500
171
Hardware Installation Manual, 12/2015, A5E33294624B AD
T1
T2
117.7
53.1
117.7
53.1
117.7
53.1
Power Module PM240-2