Figure 5-6
Connecting PM240-2 Power Modules, 200 V to 1 AC - only FSA ... FSC
Note
Connecting PM240-2 Power Modules, 200 V to 1 AC - only FSA ... FSC
For the 200 V versions and single-phase line systems, connect the phase conductor and
neutral conductor to any two of the terminals L1, L2, L3.
5.1.4

Motor cable length

Always dimension the motor cable so that the ohmic losses are less than 5 % of the inverter
power rating.
The permissible length of the motor cable also depends on the quality of the motor cable and
the inverter pulse frequency. The values specified below are applicable for high quality
cables, such as CY100 or similar, and for the pulse frequencies set in the factory.
If you set other pulse frequencies, then you must ensure that the EMC category is complied
with on the plant or system side.
Table 5- 1
Frame size
FSA ... FSC
FSD ... FSE
FSF
Power Module PM240-2
Hardware Installation Manual, 12/2015, A5E33294624B AD
Pulse frequencies (Page 86).
Maximum permissible motor cable length (m) for inverters with integrated filter and
shielded cables
200 V / 400 V
200 V / 400 V
690V
200 V / 400 V
690V
First/second envi-
Second environ-
ronment,
ment, EMC category
EMC Category C2
50
150
100
150
---
Connecting-up
5.1 Line and motor connection
No EMC category
C3
50
50
150
200
100
200
150
200
100
200